在允许的边缘依赖平均持久停留时间或允许的边缘依赖持久停留时间切换下,对于离散时间切换系统的新稳定性结果
1School of Automation, Nanjing University of Science and Technology, Nanjing, Jiangsu 210049, China.
ISA transactions
|January 9, 2024
概括
本研究介绍了离散时间系统的新型切换策略,通过改进的利亚普诺夫函数方法来增强稳定性分析,用于更广泛的应用.
科学领域:
- 控制理论 控制理论
- 系统工程 系统工程
- 应用数学 应用数学 应用数学
背景情况:
- 离散时间交换系统需要强大的稳定性分析.
- 现有的切换策略,如模式依赖的持久停留时间有局限性.
研究的目的:
- 提出一种新的可接受的边缘依赖平均持续停留时间切换策略.
- 为稳定性分析开发一个改进的多重凸起的利亚普诺夫函数方法.
- 概括现有的切换策略,并加强稳定性分析.
主要方法:
- 将允许的边缘依赖平均停留时间切换集成到模式依赖的持久停留时间切换中.
- 开发一种新的多重凸起的利亚普诺夫函数方法.
- 对离散时间交换系统的分析.
主要成果:
- 提出了一种新的允许边缘依赖平均持久停留时间切换策略.
- 新的策略比现有方法更普遍,更优越.
- 改进的利亚普诺夫函数方法允许更广泛的可行范围和更窄的边界.
结论:
- 拟议的切换策略和利亚普诺夫函数方法有效地提高了离散时间切换系统的稳定性分析.
- 这些方法通过三相逆变器和数值示例来验证.
相关概念视频
Stability
128
The time response of a linear time-invariant (LTI) system can be divided into transient and steady-state responses. The transient response represents the system's initial reaction to a change in input and diminishes to zero over time. In contrast, the steady-state response is the behavior that persists after the transient effects have faded.
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
128
BIBO stability of continuous and discrete -time systems
398
System stability is a fundamental concept in signal processing, often assessed using convolution. For a system to be considered bounded-input bounded-output (BIBO) stable, any bounded input signal must produce a bounded output signal. A bounded input signal is one where the modulus does not exceed a certain constant at any point in time.
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
398
Multimachine Stability
163
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
163
Transient and Steady-state Response
181
In control systems, test signals are essential for evaluating performance under various conditions. The ramp function is effective for systems undergoing gradual changes, while the step function is suitable for assessing systems facing sudden disturbances. For systems subjected to shock inputs, the impulse function is the most appropriate test signal.
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
181
Classification of Systems-II
146
Continuous-time systems have continuous input and output signals, with time measured continuously. These systems are generally defined by differential or algebraic equations. For instance, in an RC circuit, the relationship between input and output voltage is expressed through a differential equation derived from Ohm's law and the capacitor relation,
146
Time-Domain Interpretation of PD Control
115
Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Consider the example of control of motor torque. Initially, a positive...
115