概括
酸葡萄糖酸有效地去除根通道中的涂抹层,类似于乙烯二胺酸 (EDTA). 与EDTA不同,糖酸盐不会引起显著的牙侵蚀,使其成为更安全的根管治疗替代品.
科学领域:
- 牙周内科医院 牙周内科医院 牙周内科医院
- 牙科材料科学 牙科材料科学
背景情况:
- 根管治疗中的机械仪器创建了一个涂抹层.
- 乙二胺三酸 (EDTA) 是一种常见的化剂,用于去除涂抹层,但可以导致牙侵蚀.
研究的目的:
- 评估糖酸作为EDTA的替代品,用于去除涂抹层.
- 与EDTA相比,评估酸对牙脱的作用.
主要方法:
- 单根下前被用糖酸盐或17%的EDTA作为最终灌剂进行治疗.
- 扫描电子显微镜 (SEM) 评估了涂抹层的去除和牙侵蚀.
- 维克斯微硬度测试评估了牙脱.
主要成果:
- 糖酸的涂抹层去除效果与EDTA相比较.
- 与EDTA相比,基酸盐导致的牙侵蚀明显较小.
- 牙微硬度的降低较少与糖酸盐,虽然不是统计学意义上的.
结论:
- 酸在有效的涂抹层去除和最小的牙脱之间提供了平衡.
- 在牙周内治疗中,酸葡萄酸为EDTA提供了一个有前途的替代品.
相关概念视频
Masking and Demasking Agents
2.4K
EDTA titrations may necessitate masking and demasking agents to temporarily protect a particular metal ion in a mixture from the EDTA reaction. These agents facilitate the sequential analysis of the metal ions by forming stable complexes with some—but not all—metal ions during certain steps.
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
2.4K
EDTA: Chemistry and Properties
1.9K
Polydentate ligands are most widely used in complexometric titrations because they form more stable complexes with the metal ions than mono- or bidentate ligands due to the chelate effect. Examples of polydentate ligands are ethylenediaminetetraacetic acid (EDTA), crown ethers, and cryptands. The most important feature of optimal polydentate ligands is the ability to form 1:1 complexes in a single-step process. Amino carboxylic acid derivatives are frequently used as complexing agents. EDTA is...
1.9K
Effects of EDTA on End-Point Detection Methods
275
Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
275
EDTA: Indirect and Alkalimetric Titration
926
Unlike direct titration, back-titration, and displacement titration, indirect titration is an EDTA titration method for quantifying anions. In the indirect titration method, anions are precipitated as their insoluble salts with excess metal ions. The filtrate containing the excess metal ions is directly titrated with standard EDTA until the endpoint is achieved. Another approach involves extracting the metal ion and back-titrating with standard EDTA to obtain the endpoint. In this way, the...
926
EDTA: Auxiliary Complexing Reagents
589
EDTA titrations are usually carried out in highly basic conditions, where the fully deprotonated form of EDTA, Y4−, actively complexes with the free metal ions in the solution. Several metal ions precipitate as hydrous oxide (hydroxides, oxides, or oxyhydroxides) under these conditions, lowering the concentration of free metal ions in the solution. For this reason, auxiliary complexing agents or ligands such as ammonia, tartrate, citrate, or triethanolamine are used in EDTA titrations to...
589
EDTA: Direct, Back-, and Displacement Titration
2.8K
The EDTA titration types for metal ion analysis include direct titration, back-titration, and replacement titration.
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides...
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides...
2.8K