颗粒物中总C,N和S的同位素比率同时通过混合USGS和IAEA参考材料进行校准
Jeong Sik Lim1, Yong-Hyeon Yim2
1Research Center for Climate Metasphere, Korea Research Institute of refers and Science (KRISS), Gajeong-ro 267, Yuseong-gu, Daejeon, 34113, Republic of Korea; Science of Measurement, University of Science and Technology (UST), Gajeong-ro 217, Yuseong-gu, Daejeon, 34113, Republic of Korea.
Talanta
|January 15, 2024
概括
这项研究校准了首尔的同位素比率.
科学领域:
- 环境科学 环境科学
- 分析化学 分析化学
- 地质化学 地质化学
背景情况:
- 颗粒物 (PM) 同位素分析对于来源分配至关重要.
- 环境样本中同位素比率的准确校准具有挑战性.
- 现有的方法可能缺乏对多个元素的同时分析能力.
研究的目的:
- 开发和验证一种方法,用于同时校准颗粒物中总碳,和硫同位素的比率.
- 用国际参考材料评估开发方法的性能.
- 在首尔大都市区确定PM同位素比的参考值和不确定性.
主要方法:
- 使用了一个元素分析仪-同位素比质谱仪 (EA-IRMS).
- 使用的是美国地质调查局 (USGS) 和国际原子能机构 (IAEA) 参考材料的混合物.
- 应用通用最小平方 (GLS) 回归用于校准线路生成.
主要成果:
- 实现了同时测量碳,和硫同位素的比率.
- 碳和同位素的良好线性和可重复性被证明.
- 由于峰值扩大,观察到硫同位素的不良结果,表明局限性.
结论:
- 开发的EA-IRMS方法允许在PM中同时校准同位素比率.
- 与参考材料相比,PM同位素比率的确定不确定性更高,主要是由于同质性问题.
- 需要进一步精细化,以应对硫同位素分析的挑战,并减少整体不确定性.
更多相关视频
相关概念视频
Isotopes
Elements have a set number of protons that determines their atomic number (Z). For example, all atoms with eight protons are oxygen; however, the number of neutrons can vary for atoms of the same element. The sum of the number of protons and the number of neutrons is the mass number (A). Atoms with the same atomic number but different mass numbers are called isotopes. Elements can have multiple isotopes, for example, carbon-12, carbon-13, and carbon-14.An element's atomic mass, or weight, is a...
High-Resolution Mass Spectrometry (HRMS)
The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For example, the mass of helium...
Mass Spectrometry: Isotope Effect
Most elements exist in nature as a mixture of isotopes. The isotopes differ in weight due to their respective number of neutrons. The molecular weight of a molecule is different depending on the specific isotope of its elements involved. As a result, the mass spectrum of the molecule exhibits peaks from the same fragment at multiple positions. The positions of these mass signals depend on the mass differences between isotopes. Furthermore, the intensity of these signals is dependent on the...
Mass Spectrum: Interpretation
An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a soft-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.To...
Chemical Shift: Internal References and Solvent Effects
In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...


