基于维尔尼尔效应的高灵敏度温度传感器使用坚固的双腔纤维法布里-佩罗特干扰仪
Miguel Á Ramírez-Hernández1, Monserrat Alonso-Murias1, David Monzón-Hernández1
1Centro de Investigaciones en Óptica A. C., León 37150, Mexico.
Polymers
|January 17, 2024
概括
这项研究引入了一种高度灵敏的光纤温度传感器,使用双腔Fabry-Perot干扰仪 (DCFPI). 这种新型传感器利用弗尼耶效应来实现工业和科学应用的增强温度灵敏度.
科学领域:
- 光电学是指光电子产品.
- 传感器技术 传感器技术
- 材料科学 材料科学 材料科学
背景情况:
- 精确的温度测量在工业,科学和医疗领域至关重要.
- 现有的温度传感器在敏感度,分辨率和响应时间方面面临限制,以适用于苛刻的应用.
- 光纤传感器提供了高性能和远程传感能力的潜力.
研究的目的:
- 提出和展示一种新的,高度灵敏的光纤温度传感器.
- 通过在双腔体配置中利用弗尼耶效应来提高温度灵敏度.
- 开发一个强大的,简单的,可重新配置的传感器,用于实际应用.
主要方法:
- 使用单模光纤连接器上的聚合物盖子制造双腔Fabry-Perot干扰仪 (DCFPI).
- 优化空气腔长度 (L) 和聚合物盖厚度 (L),以诱导维尼尔效应.
- 将DCFPI包装在一个可移动的支架中,以提供可调节的空气腔长度和保护.
主要成果:
- 展示了一种具有显著改善温度灵敏度的DCFPI.
- 达到高达39.8nm/°C的温度灵敏度,性能优于标准的聚合物覆盖纤维法布里-佩罗干扰仪 (PCFPI).
- DCFPI传感器强大,易于制造,并允许简单调整空气腔.
结论:
- 拟议的DCFPI传感器通过Vernier效应有效地提高了温度灵敏度.
- 该技术为各种苛刻环境中高灵敏度温度监测提供了有前途的解决方案.
- 传感器的简单设计和坚固的包装使其在实践中实现和操作更容易.
相关概念视频
Equipments Used to Measure Body Temperature
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...