在气体吸管后,FIL SSF眼内镜片变暗:一个案例系列
L Sejournet1, S Elbany2, Y Serrar1
1Department of Ophthalmology, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, Lyon, France.
European journal of ophthalmology
|January 17, 2024
概括
无的膜固定液友眼内透镜 (FIL SSF IOL) 可能在气体吸管后变暗,特别是在接受视网膜脱落修复的患者中. 这种并发症在27.3%的气体吸管病例中被观察到,在风险患者使用这些内腔眼镜时需要谨慎.
科学领域:
- 眼科医生 眼科 眼科
- 生物材料科学 生物材料科学
背景情况:
- 无的膜固定液友眼内透镜 (FIL SSF IOL) 用于纠正阿法基亚.
- 气体吸管是一种用于修复视网膜脱落的常见程序.
研究的目的:
- 在气体吸管后报告FIL SSF IOL术后变暗的三个病例.
- 为了确定FIL SSF IOL阴暗化在气体吸管程序后的发生率.
主要方法:
- 一系列病例报告了三名患者在帕斯普拉纳视切除术或Descemet膜内皮切除术后出现了FIL SSF IOL阴暗化.
- 追溯审查FIL SSF IOL植入病例,以计算阴暗化率.
- 解释的IOL. 的组织病理学分析 (Von Kossa染色) .
主要成果:
- 在气体吸管后观察到三例FIL SSF IOL阴暗化 (2例是用C2F6进行帕斯普拉纳视切除术后,1例是用SF6进行DMEK后).
- 总的来说,FIL SSF IOL的阴暗化率为2.1% (3/140).
- 气体吸管治疗的患者中,化率明显高 (27.3%, 3/11).
结论:
- 用于视网膜脱落修复的气体吸管与FIL SSF IOL变暗的高风险有关.
- IOL表面的化被确定为不透明的原因.
- 眼科医生应在需要气体吸管的患者植入FIL SSF IOL时谨慎行事.
相关概念视频
Angle Closure Glaucoma: Treatment
500
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
500
Glaucoma: Overview
574
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
574
Open Angle Glaucoma: Treatment
453
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
Drugs such as carbonic anhydrase inhibitors, α2- and...
453