带有范德瓦尔斯道二极管的宽带微型光谱仪
Md Gius Uddin1,2, Susobhan Das1, Abde Mayeen Shafi1
1Department of Electronics and Nanoengineering, Aalto University, Espoo, 02150, Finland.
Nature communications
|January 17, 2024
概括
我们使用范德瓦尔斯的异构结构开发了一个紧的光谱仪. 这种宽带设备为芯片上和可植入的光子应用提供了高精度.
科学领域:
- 光电学是指光电子产品.
- 光子学是指光子学的使用方法.
- 材料科学 材料科学 材料科学
背景情况:
- 传统的光谱仪由于分散性组件而庞大,限制了芯片上和可植入的应用.
- 缩小对于将光谱仪集成到光子和光电子设备中至关重要.
研究的目的:
- 开发一种高性能,紧的宽带光谱仪.
- 为了克服集成应用的传统光谱仪设计的局限性.
主要方法:
- 使用了一种由二硫化和黑组成的范德瓦尔斯异构二极管.
- 利用电调光响应和计算算法进行光谱重建.
- 制造了一种具有大约30x20μm2.2的紧足迹的设备.
主要成果:
- 从大约500到1600纳米实现了广泛的操作带宽.
- 证明了高峰波长准确度约为2纳米.
- 成功实施了一种基于二极管的光谱仪方案,具有宽带功能.
结论:
- 开发的范德瓦尔斯异构二极管为小型化,高性能光谱仪提供了一个有前途的途径.
- 这种紧的宽带光谱仪适用于各种应用,包括传感,监控和光谱成像.
- 设备设计简化了芯片上和可植入光子和光电子系统的集成复杂性.
相关概念视频
UV–Vis Spectrometers
1.3K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.3K
Raman Spectroscopy Instrumentation: Overview
406
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
406
IR Spectrometers
1.2K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.2K