与气球顶临时起器相比,临时永久起器与更好的临床和安全结果有关
Maroun Chedid1, Gautam R Shroff2,3, Omer Iqbal2,3
1Department of Medicine, Hennepin Healthcare, Minneapolis, Minnesota, USA.
Pacing and clinical electrophysiology : PACE
|January 19, 2024
概括
临时永久起器 (TPPM) 为气球倾斜临时起器 (BTTP) 提供了更安全的替代方案,减少并发症,并使患者能够更早地行走. 这项研究突出了TPPMM的特点.
科学领域:
- 心脏病学 心脏病学
- 医疗器械 医疗器械
- 临床研究 临床研究
背景情况:
- 气球倾斜临时心脏起器 (BTTP) 广泛使用,但存在脱落和血栓栓塞的风险.
- 临时永久心脏起器 (TPPM) 正在作为一种替代品出现,但对比结果的数据有限.
研究的目的:
- 为了比较TPPM与BTTP的安全概况.
- 评估二次结果,包括患者出行和医疗保健利用情况.
主要方法:
- 在2014年至2022年期间,对126名接受临时起器安置的患者进行了回顾性图表审查.
- 分析主要安全结果和二次目标,如行走和医疗保健使用.
- 对TPPM和BTTP组进行比较,TPPM的下静脉接入,BTTP的股骨静脉接入.
主要成果:
- 在TPPM组,脱落,血栓栓塞和感染明显减少 (OR=0.23).
- 只有在TPPM组 (55.6%,p <.001) 中,患者的行走是可能的.
- 根据TPPM的医院监测设置,没有发现不良事件的显著差异.
结论:
- 与BTTP相比,TPPM具有更高的安全性.
- TPPM有助于提前行走,并可能减少医疗保健利用率.
相关概念视频
Electrical Energy
Using electric appliances for a longer period of time consumes more electrical energy and results in a higher electric bill. The energy produced by the transfer of electrons from one point to another is known as electrical energy. If power is delivered at a constant rate, the electrical energy can be defined as the product of power used by the device for a period of time. The energy unit on electric bills is the kilowatt-hour, where one kilowatt-hour is equivalent to 3.6 × 106 joules. The...
Insulation Coordination
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times for...
Circuit Breaker and Fuse Selection
A circuit breaker is a device engineered to interrupt fault currents and sometimes reclose automatically. When a fault current is detected, the breaker separates the electrical contacts, which generates an arc. This arc is extinguished by methods such as elongation, cooling, or splitting, depending on the breaker's design. Breakers are categorized based on the voltage they operate at and the medium used for arc extinction, such as air, oil, SF6 gas, or vacuum.
In high-voltage systems, circuit...
In high-voltage systems, circuit...
Overcurrent Relays
Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Reclosers and Fuses
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
Pilot and Numeric Relaying
Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying: