预缩技术的概述与诱导合等离子体质谱学相结合,用于在生物研究中确定微量元素
María N Oviedo1, Cecilia E Luján1, Aldana A Lemos1
1Laboratorio de Química Analítica para Investigación y Desarrollo (QUIANID), Facultad de Ciencias Exactas y Naturales, Universidad Nacional de Cuyo / Instituto Interdisciplinario de Ciencias Básicas (ICB), CONICET UNCUYO, Padre J. Contreras 1300, 5500, Mendoza, Argentina.
Analytical and bioanalytical chemistry
|January 19, 2024
概括
在生物样本中确定微量元素对于健康和环境研究至关重要. 将感应合等离子体质谱法 (ICP-MS) 与预度技术相结合,可提高超微观元素分析的准确性.
科学领域:
- 分析化学 分析化学
- 环境科学 环境科学
- 生物化学 生物化学
背景情况:
- 生物材料中微量元素的确定对于人类健康和环境监测至关重要.
- 感应合等离子体质谱 (ICP-MS) 为多元元素分析提供了高灵敏度.
- 复杂的生物矩阵和超微量元素水平需要预缩方法来提高ICP-MS的性能.
研究的目的:
- 提供使用ICP-MS.生物样本中微量元素分析的预缩技术的全面审查.
- 讨论液体和固体相提取方法和材料的进步.
- 探索元素物种化策略和自动化的影响.
主要方法:
- 对液相预缩技术的审查.
- 对固体相预缩技术的审查.
- 对色谱和非色谱物种化方法的分析.
主要成果:
- 从2000年到现在,ICP-MS应用的预缩技术的概述.
- 讨论用于微量元素提取的新型溶剂和材料.
- 检查元素物种化策略和自动化的作用.
结论:
- 预缩技术对于通过ICP-MS在生物样本中敏感和选择性地确定微量元素至关重要.
- 材料和自动化方面的进步正在改善分析方法.
- 未来的研究应该解决微量元素分析和物种化的新出现的挑战.
相关概念视频
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
744
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
744
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
622
Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
622
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
474
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
474
Mass Spectrometry: Complex Analysis
785
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
785
Atomic Emission Spectroscopy: Overview
2.2K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
2.2K
Electrogravimetric Analysis: Overview
230
Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.
To test the completeness of the...
To test the completeness of the...
230