在患有复发性复发性多发性硬化症的女性中,静止时节拍血压变异性减少
Claire E Kissell1, Benjamin E Young2, Caitlin P Jarrard2
1Department of Applied Physiology and Sport Management, Southern Methodist University, Dallas, TX, USA.
Multiple sclerosis and related disorders
|January 20, 2024
概括
与健康对照组相比,患有复发性复发性多发性硬化症 (RRMS) 的女性表现出较低的血压变化. 这种降低血压变异性与RRMS患者的交感或心脏巴罗反射灵敏度的改变无关.
科学领域:
- 神经科学是一个神经科学.
- 心血管生理学心血管生理学
- 自主神经系统的自主神经系统
背景情况:
- 心血管自主功能障碍在复发性复发性多发性硬化症 (RRMS) 中普遍存在.
- 交感神经系统功能障碍可能会影响RRMS女性的血压调节和变化.
- 情感控制受损可能导致静止时血压变化增加.
研究的目的:
- 为了研究与健康对照组相比,RRMS女性的血压变化.
- 为了确定是否降低了交感巴罗反射灵敏度与RRMS的女性增加了血压变化.
主要方法:
- 持续的心电图和鼓动到鼓动的血压记录在躺着休息期间.
- 在参与者的子集中测量肌肉交感神经活动 (MSNA).
- 使用已确定的方法量化同情心和心脏巴罗反射灵敏度.
主要成果:
- 患有RRMS的女性的血压变化 (标准偏差和四分位数范围降低) 比健康对照显著较低.
- 在休息时的平均动脉压,静脉血压,透气血压或MSNA之间没有观察到显著的差异.
- 在RRMS患者和对照人群中,交感和心脏巴罗反射灵敏度相似,与血压变化无关.
结论:
- 患有RRMS的女性表现出降低的,而不是增加的,节拍对节拍血压变化.
- 在RRMS中观察到的血压变异性降低不能归因于同情或心脏巴罗反射灵敏度的变化.
相关概念视频
Measurement of Blood Pressure
933
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
933
Decreased pulse rate
544
Bradycardia is a medical condition in which the heart rate is slower than normal. It occurs when the heart's natural pacemaker, the sinus node, generates slower electrical impulses than the standard rhythm. In adults, bradycardia is diagnosed when the pulse rate falls below 60 beats per minute, indicating a deviation from the normal heart rate range.
There are specific risk factors that can elevate the likelihood of developing bradycardia. Advanced age is a significant factor, with...
There are specific risk factors that can elevate the likelihood of developing bradycardia. Advanced age is a significant factor, with...
544
Assessment of blood pressure in brachial artery(two-step method)
711
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
711
Special considerations while measuring blood pressure
724
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
724
Pre-Procedural Guidelines for Assessing Blood Pressure
565
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
565
Assessment of blood pressure in brachial artery(one-step method)
593
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
593