颗粒大小对三酸盐定性行为的影响:使用ISO 6876隙测试和同热感应热量计的比较研究
Anarela Vassen Bernardi1,2, Marcelo Tramontin Souza3, Oscar Rubem Klegues Montedo2
1Graduate Program in Dentistry, School of Dentistry, Federal University of Rio Grande do Sul (UFRGS), Porto Alegre 90010-150, RS, Brazil.
Bioengineering (Basel, Switzerland)
|January 22, 2024
概括
较小的三酸颗粒大小可以加速水泥水化,将定时间缩短高达24%. 隙测试和热量计显示出对设置时间评估的良好相关性,偏差低于12%.
科学领域:
- 材料科学 材料科学 材料科学
- 化学工程是化学工程的重要组成部分.
- 建筑材料 建筑材料
背景情况:
- 三酸盐 (C3S) 是波特兰水泥的主要组成部分.
- 颗粒大小显著影响水泥水化动力学和设置行为.
- 标准化方法对于可靠评估水泥材料性能至关重要.
研究的目的:
- 为了研究三酸颗粒大小对水泥置行为的影响.
- 为了比较ISO 6876缩影测试和同热热度计的结果.
- 为了确定颗粒大小和水泥位特征之间的相关性.
主要方法:
- 用水与固体比率为0.66.6的水制成的水泥糊.
- 设置时间使用ISO 6876的缩测试进行评估.
- 在室温下通过同热传导热量计监测水化动力学.
主要成果:
- 减少颗粒大小加速了水泥糊的水化,将定时间缩短了高达24%.
- 从缩测试开始的最终设置时间与热量计曲点非常相匹配.
- 在不同的粒子大小中,方法偏差始终低于12%.
结论:
- 颗粒大小是控制三酸盐水化和设置的关键因素.
- 根据ISO 6876标准,缩和同热热度计是设置时间评估的补充技术.
- 方法之间的准确相关性支持可靠的水泥材料的表征.
更多相关视频
08:59Determination of Aggregate Surface Morphology at the Interfacial Transition Zone ITZ
Published on: December 16, 2019
8.1K
11:50Metal-silicate Partitioning at High Pressure and Temperature: Experimental Methods and a Protocol to Suppress Highly Siderophile Element Inclusions
Published on: June 13, 2015
12.5K
相关概念视频
Setting Time of Cement
169
The setting time of cement refers to the process of cement paste transitioning from a plastic state to a solid state. This process is crucial in construction as it dictates the timeframe for concrete placement, compaction, and finishing. The onset of this solidification is termed the initial set, indicating when the paste becomes unworkable. The final set is when the paste has solidified completely, and further handling or manipulation can no longer affect its shape. The cement strength is...
169
Hydration of Cement
237
Hydration of cement is a chemical reaction between cement particles and water. This process occurs primarily through two mechanisms: through-solution and topochemical. In the through-solution process, anhydrous compounds dissolve into their constituents, hydrates form in the solution, and then precipitate from the supersaturated solution. The topochemical process involves solid-state reactions at the cement particle surface. The through-solution process dominates the topochemical process at the...
237
Strength and Heat of Hydration
241
The hydration of cement is an exothermic reaction in which heat is generated as cement hydrates. This heat of hydration is critical to cement's strength development. The rate at which this heat is generated affects the temperature rise, with a majority of the heat being released early in the hydration process, half within the first three days, and about 75% within the first week.
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
241
Soundness of Cement
171
The soundness of cement refers to the ability of cement paste to retain its volume after setting. Unsound cement can lead to expansion and structural damage due to the presence of free lime, magnesia, and calcium sulfate. Free lime hydrates very slowly, expanding and causing unsoundness, which is difficult to detect because it intercrystallizes with other compounds. Magnesia also reacts with water, forming crystals that can disrupt the cement's structure. Calcium sulfate can create...
171
Fineness of Cement
132
The fineness of cement directly influences the rate of hydration, as the hydration begins at the surface of the cement particles. In addition to hydration, the fineness of cement is vital for various properties of concrete including workability, gypsum requirement, and long-term behavior. The fineness of cement is represented in terms of the specific surface of cement which is typically measured in square meters per kilogram, with several methods available for this determination.
Direct...
Direct...
132
Testing Water Quality
111
When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
111