智能扬声器远程多人心率监测:克服隔离约束
Thu Tran1, Dong Ma1, Rajesh Balan1
1School of Computing and Information Systems, Singapore Management University, Singapore 178902, Singapore.
Sensors (Basel, Switzerland)
|January 23, 2024
概括
这项研究引入了一种新的声学传感方法,用于同时远程监测近距离的多个人的心率. 该系统准确地检测心率,即使与最小的分离,克服以前的局限性.
科学领域:
- 生物医学工程 生物医学工程
- 信号处理 信号处理
- 人与计算机的交互
背景情况:
- 心率是健康评估的关键重要标志.
- 通过智能设备的声学传感提供非侵入性的远程心率检测.
- 现有的方法与信号干扰作斗争,限制了近距离的多用户监控.
研究的目的:
- 开发一种声学传感方法,用于同时监测近距离的多个人的心率,减少干扰.
- 为了实现实用应用,例如在共享空间中监控夫妇或团体.
主要方法:
- 利用智能扬声器原型进行声学传感.
- 开发了信号处理技术,以尽量减少用户之间的干扰.
- 在各种现实场景中进行了用户研究.
主要成果:
- 准确的同时传感两个用户坐在一起的心率,中间误差为0.66bpm.
- 成功监测最多四个个体的近距离.
- 在各种现实生活条件下表现出强性.
结论:
- 拟议的声学传感方法有效地实现了同时,近距离的心率监测.
- 这项技术克服了以前的局限性,在共享环境中开辟了远程健康传感的新途径.
相关概念视频
Factors Influencing Heart Rate
2.7K
The heart rate, or pulse rate, is a vital indicator of cardiovascular health. It reflects the number of times the heart beats per minute. Various physiological and environmental factors influence heart rate, increasing or decreasing cardiac output. Understanding these factors is crucial for assessing heart function and identifying potential health issues.
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
2.7K
Pulse rhythm
803
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
803
Pulse Oximetry
329
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
329
Special considerations while measuring pulse
580
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
580
Heart Sounds
1.9K
Heart sounds are generated by the turbulence in blood flow due to the closing of heart valves. These sounds are best perceived slightly away from the valves, where the blood flow disseminates the sound.
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
1.9K