一个多中心研究针的尺寸和安全性为骨活检
Hadiseh Kavandi1, Malak Itani1, Benjamin Strnad1
1From the Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave, Boston, MA 02215 (H.K., S.A.E., A.B., O.R.B.); Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Mo (M.I., B.S., S.M.); Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wis (M.G.L., V.N.K., J.L.H.); Department of Diagnostic Imaging, The Warren Alpert Medical School of Brown University, Rhode Island Hospital, Providence, RI (M.B., A.R.K.); Department of Radiology, Henry Ford Health, Detroit, Mich (K.K., M.O.H.); Department of Radiology, Vanderbilt University Medical Center, Nashville, Tenn (V.P.); Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Mass (D.I.G.); and Department of Radiology, University of Alabama at Birmingham, Birmingham, Ala (C.M.B., S.G.).
大孔针 (18度或更大) 对于图像引导的脏活检是安全的,其出血率与较小的针相似. 这种手术的并发症率很低,使其成为脏组织采样的可行选择.
科学领域:
- 放射学 放射学是一门学科.
- 干预性放射学 干预性放射学
- 在瘤学瘤学.
背景情况:
- 由于对出血并发症的担忧,脏活检很少进行.
- 图像引导的活检技术为获得更安全的组织提供了潜在的机会.
研究的目的:
- 为了评估大孔 (≥18尺) 图像引导的脏活检的安全性和有效性.
- 为了比较大孔和小孔针之间的并发症率,用于脏活检.
主要方法:
- 对接受美国或CT指导的脏活检的成年患者的回顾性分析 (2001年3月至2022年3月).
- 使用≥18尺针和<18尺针的活检结果的比较.
- 主要结局:显著出血,由成像检测结果或干预需要 (血管造影/手术) 定义.
主要成果:
- 大孔 (7.9%) 和小孔 (8.4%) 针之间出血率没有显著差异.
- 治疗出血率较低:大孔针的1%与小孔针的2.1%相比.
- 较小的病变大小与增加的出血风险相关 (P=.03).
- 淋巴瘤或白血病患者出血的发生率较低 (P=.05).
结论:
- 大孔针 (≥18尺) 是安全的图像引导的脏活检.
- 出血并发症的发生率与较小孔针相比较.
- 使用大孔针进行图像引导的脏活检是一种安全的程序,治疗需要较少.