一个四重直流源切换的三相多层直流链逆变器拓
S Sivamani1, S P Mangaiyarkarasi2, R Gandhi Raj3
1Department of Electrical and Electronics Engineering, E.G.S. Pillay Engineering College, Nagapattinam, 611002, Tamilnadu, India. drsivamani87@gmail.com.
Scientific reports
|January 24, 2024
概括
本研究介绍了一种新型的级联多级逆变器 (MLI) 设计,使用隔离的四电压源模块. 拟议的三相MLI减少了组件,并改善了中低功率应用的输出电压质量.
科学领域:
- 电气工程 电气工程
- 电力电子 电力电子 电力电子
背景情况:
- 级联式多级逆变器 (MLI) 在低到中功率应用中有效产生高质量的输出电压.
- MLIs将输出电压塑造为多个步骤,使用多个直流源近似一个正弦波形.
- 在MLI的一个关键挑战是越来越多的组件具有更高的电压水平.
研究的目的:
- 提出一种新的三相MLI设计,利用隔离的四电压源模块.
- 为了减少电流传导路径中的切换元件的数量.
- 为了提高输出电压的质量.
主要方法:
- 设计了一种新的三相MLI拓,结合了隔离的四电压源模块和H桥逆变器.
- 使用Matlab/Simulink进行模拟以分析操作特征.
- 构建了一个实验模块来验证模拟结果.
主要成果:
- 拟议的设计表明,减少了电流传导的开关元件.
- 观察到输出电压质量的改善,其特点是较低的THD (总波扭曲).
- 模拟和实验结果证实了拟议的MLI设计的有效性.
结论:
- 新型级联MLI设计为需要高质量的输出电压的中低功率应用提供了可行的解决方案.
- 该设计有效地减轻了与传统MLIs相关的组件计数问题.
- 减少组件数量和提高输出质量使这种设计在实际实施中具有优势.
更多相关视频
11:53The Modular Design and Production of an Intelligent Robot Based on a Closed-Loop Control Strategy
Published on: October 14, 2017
11.6K
11:44Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
10.3K
相关概念视频
The Delta-to-Delta Circuit
620
In a delta-delta configuration, the source and the load are connected in a delta manner, forming a closed loop that divides the network into three distinct phases. This configuration makes the phase voltages identical to line voltages. Assuming the sources are in positive sequence, the phase voltages can be expressed directly without having a neutral wire.
620
Generation of Three-Phase Voltage
380
A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
As the rotor...
380
Three-Phase Voltages
230
A three-phase generator produces three voltages that are equal in magnitude but have a phase difference of 120 degrees. This identical magnitude and equal phase separated voltages are known as the balanced voltages and help to minimize power loss while ensuring a steady delivery of energy to connected loads. As voltage sources in a three-phase system can be configured in a wye or a delta formation, the loads connected to these systems can also be arranged in either configuration. This...
230
Three-Phase Circuits
412
AC power distribution systems have three categories: single-phase, two-phase, and three-phase systems. The single-phase circuit, common in residential settings, typically employs a two-wire system connecting a single AC source to various loads. These circuits support standard household appliances operating at 120 volts (V) and 240 V, such as lamps, televisions, and microwaves. The first generators, Niagara Falls hydro plant installed in 1895, were two-phase and designed by Nikola Tesla. The...
412
Bridge rectifier
619
The bridge rectifier is essential in electronics for efficiently converting alternating current (AC) to direct current (DC). Comprised of four diodes configured in a bridge layout, this rectifier effectively processes both the positive and negative halves of the AC waveform, making it superior to half-wave and full-wave center-tapped rectifiers in terms of voltage regulation and output stability.
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
619
The Delta-to-Y Circuit
362
In the delta-wye circuit, the source is delta-connected, while the load is in a wye configuration. This means that the phase voltage of the delta-connected source is equal to the line voltage of the wye-connected load. The connection between two-line currents originates from the delta-connected source. The phase difference in the balanced system allows for calculating one line current given the other, utilizing the positive sequence of phases. In the delta-wye system, the phase currents in the...
362