双能X射线扫描仪对货物含量的基本局限性 原子数区分 原子数区分
Peter Lalor1, Areg Danagoulian1
1Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
概括
双能量放射系统无法可靠地区分核材料与其他货物. 由相互竞争的物理过程引起的这种根本的模两可,限制了目前在港口检测非法物质的系统.
科学领域:
- 核物理 核物理是核物理的.
- 材料科学是一种材料科学.
- 安全技术安全技术.
背景情况:
- 放射系统使用双能光子减弱扫描货物以寻找非法材料.
- 原子数 (Z) 区分对于货物扫描中的材料分析至关重要.
- 目前的系统在区分具有相似衰减特性的材料方面存在局限性.
研究的目的:
- 为了研究双能MeV放射系统的原子数区分能力.
- 了解材料差异化的基本局限性和含糊性原因.
- 评估当前商业系统在检测高Z核材料方面的有效性.
主要方法:
- 使用{6,4}MeV,{10,6}MeV和{10,4}MeV的制动辐射束进行双能量放射的分析.
- 蒙特卡洛模拟用于验证透明度测量和物质歧视.
- 理论研究光电吸收和对生产竞争.
主要成果:
- 对于不同的材料,可以发生相同的透明度测量,从而导致原子数区分的模两可.
- 这种非独特性是固有的,即使有完美的系统分辨率和没有统计噪音.
- 商用放射系统根本无法区分高Z核材料和中Z货物.
结论:
- 双能量放射学对原子数进行区分的能力在根本上受到竞争的物理过程的限制.
- 目前的商业系统不足以可靠地检测各种货物中的高Z核材料.
- 需要进一步的进展,以克服安全应用的放射性材料分析中固有的模两可.
更多相关视频
相关概念视频
X-ray Imaging
5.5K
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with...
5.5K
X-ray Diffraction of Biological Samples
3.8K
X-ray diffraction or XRD is an analytical tool that utilizes X-rays to study ordered structures such as crystalline organic and inorganic samples, polycrystalline materials, proteins, carbohydrates, and drugs.
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
3.8K
Atomic Emission Spectroscopy: Overview
2.2K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
2.2K
Atomic Absorption Spectroscopy: Interference
765
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
765
Scanning Electron Microscopy
4.2K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Fundamental Principles
Accelerated...
4.2K
Atomic Absorption Spectroscopy: Overview
2.1K
Atomic absorption spectroscopy (AAS) is a technique used to analyze elements by measuring electromagnetic radiation (EMR) absorbed by atoms, which causes them to transition to a higher-energy orbit. The most crucial step in AAS is atomization, where the analyte is converted into gas-phase atoms, typically through a flame or furnace. Some of these atoms become thermally excited in the flame, while most remain in the ground state.
When irradiated by EMR of a particular wavelength, these...
When irradiated by EMR of a particular wavelength, these...
2.1K