对三相感应电机的速度估计算法的审查
Z M S Elbarbary1, O K Al-Harbi1, Saad F Al-Gahtani1
1Department of Electrical Engineering, College of Engineering, King Khalid University, Abha, Saudi Arabia.
MethodsX
|January 31, 2024
概括
本文回顾了用于感应电机驱动的无传感器速度估计技术,这对于工业自动化至关重要. 它对方法进行了分类,详细说明了最佳应用选择的利弊.
科学领域:
- 电气工程 电气工程
- 控制系统 控制系统
- 工业自动化 工业自动化
背景情况:
- 在工业自动化中,对先进的无传感器速度估计的需求日益增加.
- 需要精细的技术来满足感应电机驱动器的各种应用要求.
研究的目的:
- 调查和审查用于感应电机驱动器的无传感器速度估计算法.
- 将现有技术分类,突出其特点,优点和缺点.
- 为了促进为特定的工业应用选择最佳的无传感器技术.
主要方法:
- 详细调查和审查无传感器速度估计算法.
- 基于性能标准的技术分类 (例如,稳定状态误差,动态行为,低速操作,参数/噪声灵敏度,复杂性,计算时间).
- 方法的比较分析,包括旋转槽波,信号注入和基于机器模型的系统.
主要成果:
- 识别无传感器电机驱动器的好处:降低成本,提高可靠性,简化硬件,提高噪声免疫力和减少维护.
- 基于关键绩效指标的技术区分.
- 突出了每个审查的无传感器速度估计技术的特定特征.
结论:
- 无传感器速度估计对于现代工业自动化至关重要.
- 技术的全面比较有助于为特定的感应电机驱动应用选择最合适的方法.
- 无传感器估计技术的进一步进步是必要的,以满足不断变化的工业需求.
相关概念视频
Three-Phase Short Circuit—Unloaded Synchronous Machine
143
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
143
Power System Three-Phase Short Circuits
88
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
88
Power in a Three-Phase Circuit
323
Three-phase systems have two configurations: the wye and delta. A star configuration can be three or four wires; in a delta configuration, the components are connected in a closed loop. Instantaneous power refers to the power value at a precise moment, and in a balanced three-phase system, it is constant. This is because the sum of the instantaneous powers in the three phases remains steady over time, despite individual fluctuations, due to the symmetry and phase relationship. The total...
323
Generation of Three-Phase Voltage
380
A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
As the rotor...
380
Wind Turbine Machine Models
134
In the growing field of wind energy, incorporating wind turbine models into transient stability analysis is essential. Induction and synchronous machines are the primary models used, with induction machines being prevalent due to their simplicity and reliability.
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
134
Inductance: Single-Phase And Three-Phase Line
191
Understanding the inductance of transmission lines is crucial for efficient design and operation in electrical power systems. This discussion delves into the inductance characteristics of single-phase two-wire and three-phase three-wire transmission lines with equal phase spacing.
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
191