直接注射电子喷雾电离质谱 (ESI-MS) 高矩阵含量蛋白质的分析:利用泰勒-阿里斯分散
Ruben Szabo1, Cynthia Nagy1, Attila Gaspar1
1Department of Inorganic and Analytical Chemistry, Institute of Chemistry, University of Debrecen, Debrecen, 4032, Hungary.
Angewandte Chemie (International ed. in English)
|January 31, 2024
概括
这项研究引入了泰勒-阿里斯分散辅助质谱法 (TADA-MS) 来直接分析治疗性蛋白质. 这种方法有效地解决了复杂样品中的干扰问题,而不需要先进行净化.
科学领域:
- 分析化学 分析化学
- 生物化学 生物化学
- 蛋白质组学是指蛋白质组学.
背景情况:
- 电子喷射电离质谱仪 (ESI-MS) 在治疗性蛋白质分析中经常面临干扰.
- 在不经净化的情况下对复杂矩阵中的蛋白质进行直接分析是具有挑战性的.
研究的目的:
- 为了证明泰勒-阿里斯 (TA) 分散在克服ESI-MS干扰方面的实用性.
- 建立泰勒-阿里斯分散辅助质谱法 (TADA-MS) 作为直接蛋白质分析的可行技术.
主要方法:
- 使用商用CE-MS仪器进行TA分散.
- 将0.5μL的样品注入一个长65厘米,50μm的每日液体中. 毛细血管.毛细血管.
- 使用1bar的压力将样品引入质谱仪.
主要成果:
- 成功证明了TA分散在缓解常见ESI-MS干扰问题的有效性.
- 展示了TA分散用于蛋白质组学分析的适用性.
- 验证了TADA-MS程序用于复杂矩阵中低扩散系数的蛋白质的直接注射分析.
结论:
- 通过ESI-MS,TADA-MS提供了一种可靠的解决方案,用于通过ESI-MS直接确定治疗性蛋白质.
- 该方法有效处理含有小型有机和无机化合物的复杂矩阵.
- 将TA分散集成到商业CE-MS仪器中是直接的,并且在分析上是有用的.
相关概念视频
Electrospray Ionization (ESI) Mass Spectrometry
839
Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
839
MALDI-TOF Mass Spectrometry
4.8K
Mass spectrometry is a powerful characterization technique that can identify and separate a wide variety of compounds ranging from chemical to biological entities, based on their mass-to-charge ratio (m/z). The instruments that allow this detection, known as mass spectrometers, have three components: an ion source, a mass analyzer, and a detector. These spectrometers differ based on the nature of their ion source and analyzers.
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
4.8K
Peptide Identification Using Tandem Mass Spectrometry
6.4K
Tandem mass spectrometry, also known as MS/MS or MS2, is an analytical technique that employs two mass analyzers. Essentially it is a series of mass spectrometers that helps isolate a particular biomolecule and then helps study its chemical properties.
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
6.4K
Matrix-Assisted Laser Desorption Ionization (MALDI)
321
Matrix-assisted laser desorption ionization (MALDI) is a powerful analytical technique used in mass spectrometry. It enables the identification and characterization of various biomolecules, including proteins, peptides, nucleic acids, and carbohydrates. MALDI spectrometry is widely employed in biological and medical research, as well as in fields like pharmacology and biochemistry.
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...
321
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
223
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
223
Mass Spectrometry: Complex Analysis
782
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
782