三种方法测量不同辐射发射率和复合材料类型的光聚合动力学
1Department of Conservative Dentistry, School of Dentistry and Dental Research Institute, Seoul National University.
Dental materials journal
|January 31, 2024
概括
这项研究比较了三种方法来测量牙科复合材料中的光聚合动力学. 结果显示动力学因测量方法,灯光设置和复合材料类型而异,需要全面的方法.
科学领域:
- 牙科材料科学 牙科材料科学
- 聚合物化学 聚合物化学
背景情况:
- 光聚合动力学显著影响牙复合材料的性能,如固化时间和机械强度.
- 了解这些动力学对于优化临床应用中复合材料性能至关重要.
研究的目的:
- 为了比较温度,热流和聚合缩小方法来测量复合材料光聚合动力学.
- 评估不同类型的复合材料中不同光照射量和曝光时间如何影响动力学.
主要方法:
- 测量了两种可包装和两种可流动复合材料的光聚合动力学,使用LED光 (2100 mW/cm220秒).
- 可包装复合材料的辐射发射量和曝光时间不同.
- 对于每个方法的最大温度上升,热量流和收缩率的确定峰值时间.
主要成果:
- 在这三种测量方法中,光聚合动力学显著不同.
- 动力学受到辐射发射率和复合材料类型 (可包装与可流动) 的变化的影响.
- 峰值时间因温度,热量流量或收缩率的测量而有所不同.
结论:
- 测量方法的选择会影响光聚合动力学的评估.
- 复合材料类型和光参数 (辐射发射量,曝光时间) 在动力学中起着至关重要的作用.
- 对复合材料光聚合动力学的全面理解需要使用多种测量技术.
相关概念视频
Measuring Reaction Rates
25.1K
Polarimetry finds application in chemical kinetics to measure the concentration and reaction kinetics of optically active substances during a chemical reaction. Optically active substances have the capability of rotating the plane of polarization of linearly polarized light passing through them—a feature called optical rotation. Optical activity is attributed to the molecular structure of substances. Normal monochromatic light is unpolarized and possesses oscillations of the electrical...
25.1K
Photoluminescence: Applications
401
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
401
Fluorescence and Phosphorescence: Instrumentation
603
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
603
Flame Photometry: Lab
247
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
247