一个混合蝶算法在微电网的最佳经济运行中
Guohao Sun1, Sen Yang1, Shouming Zhang1
1School of Information Engineering and Automation, Kunming University of Science and Technology, Kunming 650500, China.
Mathematical biosciences and engineering : MBE
|February 2, 2024
概括
一个新的混合蝶算法 (HBOA) 优化了微电网 (MG) 运营,大大降低了成本. 这种先进的方法提高了岛屿和电网连接的MG系统的效率.
科学领域:
- 电气工程 电气工程
- 计算机科学 计算机科学
- 优化算法 优化算法
背景情况:
- 微电网 (MG) 系统正在迅速发展,因为可再生能源的整合增加.
- 最佳的经济运行是有效管理MG系统的关键挑战.
- 降低整体发电成本是可持续的MG运营的主要目标.
研究的目的:
- 为微电网的经济运行提出一种新的优化算法.
- 提高MG系统优化算法的准确性和融合速度.
- 为了降低各种运营模式中的微电网的运营成本.
主要方法:
- 开发一个混合蝶算法 (HBOA),结合自适应切换值.
- 实施多样性学习机制,以改善人口信息交换.
- 利用精英指导的指导策略来加速算法融合.
- 使用10个标准测试函数和微电网系统的模拟实验进行验证.
主要成果:
- 与测试函数的其他方法相比,HBOA算法证明了优越的优化准确性和更快的融合.
- 在岛屿微电网模式下,HBOA实现了高达11.7%的运营成本削减.
- 在连接到电网的微电网模式下,HBOA实现了高达17.7%的运营成本降低.
结论:
- 拟议的HBOA在解决微电网中最佳经济运行问题方面是有效和优越的.
- 在岛屿和电网连接的微电网配置中,HBOA提供了显著的成本节约.
- 算法的自适应机制和指导策略有助于提高其性能.
更多相关视频
05:30Large Scale Energy Efficient Sensor Network Routing Using a Quantum Processor Unit
Published on: September 8, 2023
561
10:36Author Spotlight: Optimization of Airflow Velocities in Battery Cooling Systems for Enhanced Thermal Performance and Reduced Energy Consumption
Published on: November 3, 2023
1.5K
相关概念视频
Fast Decoupled and DC Powerflow
192
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
192
Multimachine Stability
158
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
158
Maximum Power Flow and Line Loadability
116
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
116
The Power Flow Problem and Solution
221
Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk, phase angle δk, real power Pk, and reactive power Qk. Two of these four variables are inputs, while the...
221
Bus Impedance Matrix
121
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
121
Reducing Line Loss
154
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
154