对14-15 MeV的 (n,3He) 反应截面进行系统分析
1Physics Department, Faculty of Sciences, Ferhat ABBAS, Setif-1, University, Setif, Algeria; Dosing, Analysis and Characterization in High-Resolution Laboratory, Ferhat ABBAS, Setif-1 University, Setif, Algeria.
概括
一个新的实证公式简化了计算中子诱导 (n,3He) 反应截面. 该方法使用关键核参数和实验数据准确预测14-15 MeV的截面.
科学领域:
- 核物理学 核物理 核物理
- 核反应的横截面.
背景情况:
- 了解中子诱导 (n,3He) 反应动态至关重要.
- 计算横截面的现有方法可能很复杂.
研究的目的:
- 开发一种新的,简单的实证公式,用于快速计算 (n,3He) 反应截面.
- 为预测在特定中子能量范围内的这些截面提供可靠的方法.
主要方法:
- 通过将现有的截面公式与实验数据相结合,得出了一个新的经验公式.
- 该公式包含了A23参数,值能量 (E) 和发生中子能 (E).
主要成果:
- 提出的实证公式为14-15 MeV的 (n,3He) 反应截面提供了令人满意的结果.
- 该公式的预测与实验结果一致.
结论:
- 开发的经验公式为确定 (n,3He) 反应截面提供了一种高效和准确的方法.
- 这种方法对于中子能量在14-15 MeV之间特别有用.
更多相关视频
14:11Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
26.7K
16:11Thermochemical Studies of NiII and ZnII Ternary Complexes Using Ion Mobility-Mass Spectrometry
Published on: June 8, 2022
2.3K
相关概念视频
Atomic Emission Spectroscopy: Overview
2.2K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
2.2K
Mass Analyzers: Common Types
612
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
612
Mass Analyzers: Overview
677
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
677
¹H NMR: Complex Splitting
1.3K
A proton M that is coupled to a proton X results in doublet signals for M. However, NMR-active nuclei can be simultaneously coupled to more than one nonequivalent nucleus. When M is coupled to a second proton A, such as in styrene oxide, each peak in the doublet is split into another doublet.
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...
1.3K
