电力需求分析和预测:加达经济特区的情况
Meskerem Tadesse Gebre1, Junseok Hwang2, Getachew Biru3
1Department of Technology and Innovation Management, Adama Science and Technology University (ASTU), Adama, Ethiopia.
Heliyon
|February 8, 2024
概括
埃塞俄比亚 埃塞俄比亚 埃塞俄比亚
科学领域:
- 能源经济学 能源经济学
- 可持续发展 可持续发展 可持续发展
- 经济预测 经济预测
背景情况:
- 埃塞俄比亚因经济增长而面临不断增长的电力需求.
- 可持续能源对于新的工业和经济区至关重要.
- 准确的预测对于基础设施规划至关重要.
研究的目的:
- 从2025年到2040年,预测埃塞俄比亚新经济区的电力需求.
- 在基线,积极和保守的发展场景下分析需求.
- 为可持续能源战略和基础设施发展提供信息.
主要方法:
- 使用了自下而上的预测方法.
- 采用了远程能源替代方案规划 (LEAP) 系统软件.
- 分析了住宅,工业和一般商业部门的需求.
主要成果:
- 预计到2040年,需求增长率为52.2% (基线),68% (积极) 和30.3% (保守).
- 到2040年,国家电网需求可能会增加93.5% (参考) 到175.9% (积极).
- 现场离网发电可以满足25%的需求,减少对国家电网的依赖.
结论:
- 埃塞俄比亚新经济区的电力需求预计将大幅增加.
- 需要在发电和配电方面进行大量投资.
- 集成现场离网解决方案对于可持续的能源供应至关重要.
相关概念视频
Secondary Distribution
85
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
85
Distribution Reliability and Automation
107
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
107
Electrical Power
3.1K
Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...
3.1K
Power in a Three-Phase Circuit
322
Three-phase systems have two configurations: the wye and delta. A star configuration can be three or four wires; in a delta configuration, the components are connected in a closed loop. Instantaneous power refers to the power value at a precise moment, and in a balanced three-phase system, it is constant. This is because the sum of the instantaneous powers in the three phases remains steady over time, despite individual fluctuations, due to the symmetry and phase relationship. The total...
322
Load-frequency control
165
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
165
Maximum Power Flow and Line Loadability
116
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
116