岛屿直流微电网的新综合故障检测和控制方案:一种弹性方法
Babak Zareinia1, Amir Rikhtehgar Ghiasi1, Mohammad Ali Badamchizadeh1
1Control Engineering Department, Faculty of Electrical and Computer Engineering,University of Tabriz, Iran.
ISA transactions
|February 8, 2024
概括
本研究介绍了岛屿直流微电网的弹性集成故障检测和控制模块. 新的设计提高了可靠性,并使用多目标方法减轻了变化,以提高系统性能.
科学领域:
- 电气工程 电气工程
- 控制系统 控制系统
- 电力系统 电力系统
背景情况:
- 孤立的直流微电网需要强大的故障检测和控制,以确保可靠的运行.
- 参数变化和不确定性对微电网的稳定性和性能构成重大挑战.
研究的目的:
- 开发适应性强的集成故障检测和控制模块,用于岛屿直流微电网.
- 通过多目标方法提高微电网可靠性并减轻变化.
主要方法:
- 一种多目标的方法,将控制和诊断目标作为线性矩阵不平等 (LMI) 制定.
- 基于稳定性,干扰减缓和故障检测所需的性能指数的设计.
- 开发一个算法来实现集成模块.
主要成果:
- 拟议的模块同时提高了可靠性,并减轻了DC微电网的变化.
- 该设计确保了系统的稳定性,减轻了干扰和不确定性,并检测了故障.
- 该模块证明了对自身变化的稳定性,并检测了不可补偿的故障.
结论:
- 集成故障检测和控制模块提供了一个独特的解决方案,用于增强岛屿直流微电网的弹性.
- 基于LMI的多目标方法有效地解决了控制和诊断目标.
- 对比研究验证了拟议方法的有效性,并突出了传统坚固设计的局限性.
更多相关视频
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
1.6K
08:35Interactive and Visualized Online Experimentation System for Engineering Education and Research
Published on: November 24, 2021
2.4K
相关概念视频
Reclosers and Fuses
107
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
107
Line Protection with Impedance Relays
81
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
81
Directional Relays
113
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
113
Power System Three-Phase Short Circuits
85
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
85
Bus Impedance Matrix
120
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
120
Load-frequency control
165
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
165