宽容失调的平面螺旋线圈对设计用于13.56 MHz的无线电阻模拟被动传感器的感应合
Babak Noroozi1, Bashir I Morshed2
1Electrical and Computer Engineering Department, FAMU-FSU College of Engineering, Tallahassee, FL 32310, USA.
Sensors (Basel, Switzerland)
|February 10, 2024
概括
这项研究通过优化印刷螺旋线圈 (PSC) 来增强用于日常健康监测的无线可穿戴传感器. 改进的设计最大限度地提高了传感器的灵敏度和对运动的弹性,确保可靠的生理数据收集.
科学领域:
- 生物医学工程 生物医学工程
- 可穿戴技术可穿戴技术
- 传感器设计 传感器设计
背景情况:
- 通过可穿戴传感器长期监测生理数据,为健康和临床试验带来了显著的好处.
- 之前的工作引入了一个低成本的无线电阻模拟被动 (WRAP) 传感器,使用打印的螺旋线圈 (PSC) 进行生物信号监控.
- 优化传感器灵敏度至关重要,但之前没有解决线圈错位的影响.
研究的目的:
- 优化印刷螺旋线圈 (PSC) 和相关组件,以提高可穿戴生物信号监控的灵敏度.
- 为了提高WRAP传感器系统对物理运动和线圈错位的弹性.
- 开发一个更强大,更可靠的系统,以长期监测日常生活中的身体信号.
主要方法:
- 利用基因算法优化初级和二级打印螺旋线圈 (PSC) 的设计.
- 在优化过程中纳入了线圈错位 (侧向和轴向位移).
- 在各种位移条件下评估传感器灵敏度和性能.
主要成果:
- 在1.3m的最大传感器灵敏度与16毫米的轴距离为特定的方形卷轴对 (60毫米初级,20毫米二级).
- 达到0.65m以上的灵敏度,即使侧移±11.25mm和轴移+14mm.
- 与以前的设计相比,对线圈运动的弹性有显著的改善.
结论:
- 优化的PSC设计提高了WRAP传感器系统的灵敏度和稳定性.
- 这种改进的传感器技术适用于可靠的,长期的日常生活生理监测.
- 这些发现有助于推进不引人注目的和有效的可穿戴健康监测解决方案.
相关概念视频
Magnetic Field Due to Two Straight Wires
2.5K
Consider two parallel straight wires carrying a current of 10 A and 20 A in the same direction and separated by a distance of 20 cm. Calculate the magnetic field at a point "P2", midway between the wires. Also, evaluate the magnetic field when the direction of the current is reversed in the second wire.
2.5K
Magnetic Field Due To A Thin Straight Wire
4.8K
Consider an infinitely long straight wire carrying a current I. The magnetic field at point P at a distance a from the origin can be calculated using the Biot-Savart law.
4.8K
Magnetic Field Of A Current Loop
4.6K
Consider a circular loop with a radius a, that carries a current I. The magnetic field due to the current at an arbitrary point P along the axis of the loop can be calculated using the Biot-Savart law.
4.6K
Inductance: Solid Cylindrical Conductor
262
To calculate the inductance of a solid cylindrical conductor, consider a 1-meter section of a non-magnetic, current-carrying conductor with radius r. Disregarding end effects and assuming uniform current density, Ampere's law helps determine the magnetic field inside the conductor. This law states that the magnetic field intensity H is concentric and constant within the conductor.
Given the uniform current distribution, the magnetic field Hx and flux density Bx inside the conductor are...
Given the uniform current distribution, the magnetic field Hx and flux density Bx inside the conductor are...
262
Mutual Inductance
2.3K
Inductance is the property of a device that tells us how effectively it induces an emf in another device. In other words, it is a physical quantity that expresses the effectiveness of a given device.
When two circuits carrying time-varying currents are close to one another, the magnetic flux through each circuit varies because of the changing current in the other circuit. Consequently, an emf is induced in each circuit by the changing current in the other. Therefore, this type of emf is called...
When two circuits carrying time-varying currents are close to one another, the magnetic flux through each circuit varies because of the changing current in the other circuit. Consequently, an emf is induced in each circuit by the changing current in the other. Therefore, this type of emf is called...
2.3K
Magnetic Force On Current-Carrying Wires: Example
1.5K
In a magnetic field, moving charges encounter a force. If a wire contains these moving charges, i.e., if the wire is carrying a current, then a force acts on the wire as well. Consider a pair of flexible leads holding a wire that is 40 cm long and 10 g in weight in a horizontal position. The wire is placed in a constant magnetic field of 0.40 T, as shown in Figure 1(a). Determine the magnitude and direction of the current flowing in the wire needed to remove the tension in the supporting leads.
1.5K