对于里埃变换的非线性频率调制,离子运动质谱学提高了实验效率
Elvin R Cabrera1, Robert L Schrader2, Thomas E Walker2
1Department of Chemistry, Washington State University, Pullman, WA 99164, United States.
概括
我们开发了非线性牙频率扫描用于里埃变换离子移动性质谱 (FT-IM-MS) 以提高信号质量. 这种方法提高了小型分子和大型蛋白质复合体的信号噪声比.
科学领域:
- 分析化学 分析化学
- 频谱测量是一种光谱测量.
- 物理化学 物理化学
背景情况:
- 传统的里叶变换离子移动性质谱法 (FT-IM-MS) 使用线性频率扫描.
- 线性扫描面临来自离子门低效率,小离子包和门耗尽的局限性.
- 这些因素通过限制信号采集来限制FT-IM-MS的性能.
研究的目的:
- 为FT-IM-MS.开发一种替代的离子调制策略.
- 在FT-IM-MS实验中改善信号噪声比 (SNR) 和分辨率.
- 为了克服与传统的线性频率扫描相关的局限性.
主要方法:
- 开发了非线性牙形频率扫描器.
- 优化的终端频率和有效的抽样率为扫描.
- 在高SNR和低SNR过渡的FT-IM-MS实验中应用了牙扫描.
主要成果:
- 对低质量的四基盐 (<1000 m/z) 实现了高SNR信号,分辨能力>500.
- 对于大型蛋白质复合体 (斯特列塔维丁,GroEL) 的低SNR数据,SNR显著增加.
- 展示了蛋白质复合体的改进的重建到达时间分布.
结论:
- 非线性牙频率扫描为FT-IM-MS提供了有效的替代方案.
- 这种方法提高了数据质量,特别是对于像蛋白质复合体这样的低SNR样品.
- 优化的扫描可以扩展短暂信号或实现高效的信号平均,从而提高FT-IM-MS的性能.
相关概念视频
Mass Analyzers: Common Types
610
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
610
Mass Spectrometers
5.5K
This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
5.5K
Tandem Mass Spectrometry
1.0K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and signal-to-noise ratio for the analyte. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
1.0K
Mass Analyzers: Overview
670
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
670
Mass Spectrometry: Overview
5.2K
Mass spectrometry is an analytical technique used to determine the molecular mass and molecular formula of a compound. The basic principle of mass spectrometry is to generate ions from the analyte molecule and measure these ion abundances against their molecular mass. One common type of ionization, known as electrospray ionization or EI, bombards the analyte molecules in the gas phase with high-energy electron beams. The electron beams displace an electron from the molecule and leave...
5.2K
NMR Spectrometers: Resolution and Error Correction
696
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
696