Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

7.0K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
7.0K

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Investigating the Plasmon Resonances of Silicon Nanowires without Oxide Shell.

ACS omega·2026
Same author

Longitudinal Monitoring of Metabolic Gradients in Microreactor Culture Platforms by Raman Spectroscopy.

Biosensors·2026
Same author

Design of an Amphiphilic Anion toward High Loading Solid-State Lithium Metal Battery.

Small (Weinheim an der Bergstrasse, Germany)·2026
Same author

Real-space observation of flat-band ultrastrong coupling between optical phonons and surface plasmon polaritons.

Nature materials·2025
Same author

Emission enhancement of colloidal quantum dots confined in double disc nano-antennas with controlled opening.

Nanoscale·2025
Same author

Engineered Protein-Based Ionic Conductors for Sustainable Energy Storage Applications.

Advanced materials (Deerfield Beach, Fla.)·2025

相关实验视频

Updated: Jul 3, 2025

Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets
06:12

Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets

Published on: March 17, 2023

1.4K

放大传感能力:通过多变量分析结合等离子体共振和弗雷内尔反射.

Jaione Etxebarria-Elezgarai1, Luca Bergamini2,3, Eneko Lopez1,4

  • 1CIC nanoGUNE BRTA, Tolosa Hiribidea 76, San Sebastian, 20018, Spain.

Small methods
|February 14, 2024
PubMed
概括

这项研究通过使用金纳米光盘和机器学习来提高生物传感性能. 这种创新方法显著提高了分析灵敏度和传感器分辨率,以改善检测.

关键词:
弗雷斯内尔的反射是新鲜的克雷奇曼配置的配置.局部化的表面等离子体多变量分析多变量分析.部分最小正方形.等离子体纳米结构的结构.等离子体表面格子共振.

更多相关视频

Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures
08:01

Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures

Published on: November 21, 2019

7.1K
Measurement of Scattering Nonlinearities from a Single Plasmonic Nanoparticle
15:06

Measurement of Scattering Nonlinearities from a Single Plasmonic Nanoparticle

Published on: January 3, 2016

12.9K

相关实验视频

Last Updated: Jul 3, 2025

Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets
06:12

Multimodal Analytical Platform on a Multiplexed Surface Plasmon Resonance Imaging Chip for the Analysis of Extracellular Vesicle Subsets

Published on: March 17, 2023

1.4K
Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures
08:01

Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures

Published on: November 21, 2019

7.1K
Measurement of Scattering Nonlinearities from a Single Plasmonic Nanoparticle
15:06

Measurement of Scattering Nonlinearities from a Single Plasmonic Nanoparticle

Published on: January 3, 2016

12.9K

科学领域:

  • 纳米技术纳米技术
  • 生物感应是一种生物感应.
  • 光学是什么?光学是什么?光学是什么?

背景情况:

  • 多变量分析通过提取关键信息和减轻噪音来改善生物传感.
  • 等离子传感器为检测介电变化提供高灵敏度.

研究的目的:

  • 为了提高生物传感性能,使用金纳米光盘作为Kretschmann设置中的元表面.
  • 利用机器学习和多变量分析来提高分析灵敏度和分辨率.

主要方法:

  • 使用金纳米光盘作为一个Kretschmann配置中的 metasurface.
  • 采用机器学习来分析反射率曲线中的特征.
  • 整合了超表面与微流体室,以结合弗雷内尔反射.

主要成果:

  • 工程超表面产生了超出经典克雷茨曼共振的新型等离子体特征.
  • 集成装置提供了来自弗雷内尔反射的额外光谱特征.
  • 多变量分析使分析灵敏度提高了200%以上,传感器分辨率提高了20%,预测误差减少了40%.

结论:

  • 塑元表面和弗雷内尔反射的组合显著提高了生物感知能力.
  • 这种方法提供了可用于通常可用的设置的增强检测性能.