光谱子:使用光电子子进行单样样本光谱学
Mohammad Asif Zaman1, Mo Wu1, Wei Ren1
1Department of Electrical Engineering, Stanford University, Stanford, California 94305, USA.
概括
光谱子是光电子子 (OET) 和光谱学的结合. 这种方法使用一个光束来捕捉和分析,使单个微样本的隔离和光谱测量用于生物分析.
科学领域:
- 光学和光谱学,以及光学和光谱学.
- 微流体学和纳米技术
- 生物物理学的生物物理.
背景情况:
- 光电子子 (OET) 能够精确地操纵微型样品.
- 光谱分析提供了关于样品的详细化学和物理信息.
- 单个微样本的同时操纵和表征仍然是一个挑战.
研究的目的:
- 提出一种新的综合方法,将光电子子和光谱学结合起来.
- 证明将单个微样本从集群中分离出来进行分析的能力.
- 为了验证从单个样本中获得特征性光谱特征的验证.
主要方法:
- 开发使用单一聚焦光束用于OET捕捉和光谱探测的"光谱子".
- 将光谱分析能力集成到传统的OET光学设置中.
- 从聚合种群中单个微样本的实验隔离和光谱表征.
主要成果:
- 成功同时操纵和单个微样本的光谱表征.
- 获取单个样本类型的独特光谱特征.
- 证明该方法在从集群中分离特定样本方面的有效性.
结论:
- 光谱针方法提供了微样本的同时操纵和光谱表征.
- 该方法产生了特征的光谱特征,促进了样本的识别.
- 这种技术可以很容易地集成到现有的OET系统中,为生物分析应用提供了一个方便的工具.
相关概念视频
UV–Vis Spectrometers
1.3K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.3K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
221
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
221
Atomic Emission Spectroscopy: Instrumentation
422
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
422
Tandem Mass Spectrometry
1.0K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and signal-to-noise ratio for the analyte. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
1.0K