使.

Mohd Zahirasri Mohd Tohir1,2, César Martín-Gómez1

  • 1Department of Construction, Building Services and Structures, Universidad de Navarra, Pamplona, Navarre, Spain.

Open research Europe
|February 19, 2024
PubMed
概括

电动汽车 (EV) 发生火灾的风险越来越大. 本研究使用断层树分析 (FTA) 来评估电动汽车火灾的原因和频率,为安全策略提供关键数据.

相关概念视频

Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
88
Design Example: Automobile Ignition System01:14

Design Example: Automobile Ignition System

The automobile's ignition system plays a vital role by ensuring the timely ignition of the fuel-air mixture in each cylinder. This ignition is facilitated by a spark plug, which is composed of two electrodes separated by an air gap. A spark forms across this air gap when a substantial voltage is generated between the electrodes, leading to the ignition of the fuel.
One can generate a large voltage using a car battery of 12 volts with the help of inductors. Inductors are known for opposing...
231
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
85
Bus Impedance Matrix01:24

Bus Impedance Matrix

Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
120
Circuit Breaker and Fuse Selection01:23

Circuit Breaker and Fuse Selection

A circuit breaker is a device engineered to interrupt fault currents and sometimes reclose automatically. When a fault current is detected, the breaker separates the electrical contacts, which generates an arc. This arc is extinguished by methods such as elongation, cooling, or splitting, depending on the breaker's design. Breakers are categorized based on the voltage they operate at and the medium used for arc extinction, such as air, oil, SF6 gas, or vacuum.
In high-voltage systems,...
104
Fast Decoupled and DC Powerflow01:24

Fast Decoupled and DC Powerflow

The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
192