在高血压患者中使用心血管变异和动脉硬的自主功能的非侵入性参数:系统性审查
Jia Hui Ooi1,2, Renly Lim3, Hansun Seng4,5
1Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, 50603, Kuala Lumpur, Malaysia.
Biomedical engineering online
|February 20, 2024
概括
非侵入性的自主功能指标,如巴罗反射灵敏度,显示出与高血压中动脉硬的显著联系. 这表明,在高血压患者中,早期发现心血管疾病风险的可能性很大.
科学领域:
- 心血管生理学心血管生理学
- 自主神经系统功能 自主神经系统功能
- 高血压研究 高血压研究
背景情况:
- 高血压与自主功能障碍和动脉硬有关,但非侵入性自主指标和动脉硬之间的关系尚不清楚.
- 节拍对节拍的生理变异为评估自主功能障碍提供了可访问的方法.
- 本综述研究了非侵入性自主功能标志物与高血压患者的动脉硬之间的关联.
结论:
- 高血压涉及自主调节的改变和一些心血管信号和动脉硬之间的显著关联.
- 对自主功能和动脉重塑的非侵入性监测可以改善高血压中心血管疾病风险识别.
- 了解这些关系可能会导致更个性化的高血压治疗策略.
相关概念视频
Assessment of blood pressure in brachial artery(two-step method)
708
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
708
Special considerations while measuring blood pressure
724
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
724
Assessment of blood pressure in brachial artery(one-step method)
591
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
591
Sites for measruring blood pressure
1.7K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.7K
Equipments Used To Measure Blood Pressure
972
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
972
Pulse
511
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
511