在秘鲁成年人中,与高血压危机相关的流行,趋势和因素
Victor Calderon-Ocon1, Fiorella Cueva-Peredo1, Antonio Bernabe-Ortiz1
1Universidad Científica del Sur, Lima, Perú.
Cadernos de saude publica
|February 21, 2024
概括
秘鲁的高血压危机患病率在2014-2022年期间下降. 诸如男性性别,年龄,城市生活,高BMI和糖尿病等因素增加了风险,而教育,社会经济地位和高度降低了风险. 需要改善高血压控制.
科学领域:
- 流行病学 流行病学
- 心血管健康 心血管健康
- 资源有限的环境中的公共卫生.
背景情况:
- 在资源有限的地区,高血压危机流行病学研究不足.
- 了解人口层面的趋势和风险因素对于公共卫生干预至关重要.
研究的目的:
- 确定秘鲁高血压危机的流行率和时间趋势.
- 确定与秘鲁成年人高血压危机相关的因素.
主要方法:
- 2014-2022年秘鲁人口和家庭健康调查 (ENDES) 的二次数据分析.
- 定义高血压危机为静缩血压≥180mmHg或静缩血压≥110mmHg.
- 使用多项逻辑回归和Cochrane-Armitage测试进行分析.
主要成果:
- 整体高血压危机患病率为1.5% (高血压患者中为5.7%).
- 患病率显著下降,从2014年的1.7%降至2022年的1.4% (p=0.001).
- 相关因素包括男性性别,年龄较大,城市居住,高BMI和2型糖尿病;高等教育,社会经济地位和高度显示反向关联.
结论:
- 在秘鲁观察到高血压危机的下降趋势.
- 需要有针对性的干预措施来改善高血压的诊断,治疗和控制,特别是高血压危机.
相关概念视频
Factors affecting Blood pressure
3.2K
Several physiological and lifestyle factors influence blood pressure (BP). Understanding these factors is crucial as they are significant in patient education and blood pressure management.
Physiological Factors:
Physiological Factors:
3.2K
Measurement of Blood Pressure
926
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
926
Hypertension and Regulation of Blood Pressure
2.1K
Hypertension, the most common cardiovascular disease, is diagnosed through repeated measurements of elevated blood pressure. Its risks, including damage to the kidney, heart, and brain, are directly proportional to blood pressure levels. Starting from 115/75 mm Hg, the risk of cardiovascular disease doubles with each increment of 20/10 mm Hg. The diagnosis relies on blood pressure measurements, not on patient symptoms, as hypertension is often asymptomatic until end-organ damage is imminent or...
2.1K
Errors occurring during blood pressure monitoring
726
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
726
Alterations in Blood Pressure
1.2K
Alterations in blood pressure, such as hypertension (high blood pressure) and hypotension (low blood pressure), significantly affect human health. Understanding these conditions' classifications, causes, and symptoms is essential for effective management and treatment.
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
1.2K
Special considerations while measuring blood pressure
724
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
724