通过标准传输电子显微镜对病毒颗粒进行高分辨率成像的创新无污染技术
Raja Muthuramalingam Thangavelu1, Washington Luis da Silva1
1Department of Plant Pathology and Ecology, The Connecticut Agricultural Experiment Station, New Haven, CT, USA.
Heliyon
|February 23, 2024
概括
这项研究引入了一种新的方法,用于使用传输电子显微镜 (TEM) 进行高分辨率的病毒成像,而无需有毒污点. 该方法增强了病毒结构分析和诊断,特别是对于像Begomovirus这样的植物病毒.
科学领域:
- 结构生物学是结构生物学.
- 病毒学 病毒学
- 显微镜的使用方法
背景情况:
- 电子显微镜 (EM) 对于病毒结构分析至关重要.
- 传统的EM方法需要复杂的样本准备和风险污染.
- 有毒染色程序可以改变病毒结构.
研究的目的:
- 开发一种新的高分辨率病毒成像技术.
- 克服传统电磁波的局限性,包括有毒染色和污染.
- 为了实现植物病毒的先进结构分析.
主要方法:
- 采样采集,净化和结晶的贝戈莫病毒颗粒.
- 传输电子显微镜 - 选择区域电子衍射 (TEM-SAED) 分析.
- 标准传输电子显微镜 (TEM) 用于2D和3D成像.
主要成果:
- 实现了Begomovirus的高分辨率,非外结构成像.
- 在Begomovirus粒子中证实了双胞胎二面体对称性.
- 通过结晶过程证明了高图像质量.
结论:
- 开发的方法使得高质量的病毒成像能够在没有有毒染色的情况下实现.
- 这种方法为病毒结构分析和诊断提供了新的途径.
- 通过这种技术,病毒研究和诊断的进步是可能的.
相关概念视频
Transmission Electron Microscopy
5.5K
In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400...
5.5K
Overview of Electron Microscopy
9.1K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
9.1K
Immunogold Electron Microscopy
4.0K
Immunoelectron microscopy utilizes immunogold labeling of endogenous proteins with specific antibodies to detect and localize these proteins in cells and tissues. The procedure provides insights into the distribution and quantification of protein under different stimulation conditions offering clues about their functions. Conjugating highly electron-dense gold particles with primary or secondary antibodies allow antigen detection on and within cells, with high resolution and specificity.
4.0K
Cryo-electron Microscopy
3.3K
Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...
3.3K
Super-resolution Fluorescence Microscopy
7.0K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
7.0K
Electron Microscope Tomography and Single-particle Reconstruction
2.4K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.4K


