在基于电流缩放,源退化电阻和电流再利用的神经记录放大器设计中的电源噪声优化
Zhen Wang1,2, Xiao Wang1,2, Guijun Shu1,2
1State Key Laboratory of Digital Medical Engineering, School of Biomedical Engineering, Hainan University, Haikou 570100, China.
Biosensors
|February 23, 2024
概括
这项研究引入了一种新的低功耗,低噪音的神经信号放大器用于神经记录. 它可以降低功耗和噪音,提高神经数据采集效率.
科学领域:
- 生物医学工程 生物医学工程
- 集成电路设计 集成电路设计
- 神经科学仪器仪器仪器仪表
背景情况:
- 神经记录需要具有高灵敏度和低功耗的放大器.
- 现有的放大器经常面临噪声性能,功率效率和面积之间的权衡.
- 在CMOS技术的进步使得能够设计紧而高效的神经放大器.
研究的目的:
- 设计和制造一个低功耗,低噪音的神经信号放大器,以改善神经记录.
- 为了最大限度地降低电流消耗,同时减少输入引用噪声.
- 为了评估放大器的性能,使用关键指标,如增益,带宽,噪声和功率效率.
主要方法:
- 利用当前缩放技术来降低放大器功耗.
- 结合源退化电阻和电流再利用技术来降低输入引用噪声.
- 使用0.18μm CMOS MS RF G工艺制造了放大器.
主要成果:
- 实现了40dB/46dB的中频带增益和0.54Hz至6.1kHz的带宽.
- 测量输入参考噪声为3.1μVrms,电流消耗为3.8μA,电源为1.8V.
- 显示噪声效率系数 (NEF) 为2.97和活性面积为0.082mm2.
结论:
- 设计的神经信号放大器有效平衡低功耗和低噪声性能.
- 放大器的规格适用于先进的神经记录应用.
- 制造的集成电路证明了在紧的CMOS过程中实现高性能神经放大器的可行性.
相关概念视频
Design Example: Vintage Mixing Console
231
A sound engineer at a music company recently encountered a problem. The output from their newly acquired studio's vintage mixing console was too low for the requirements of modern recording equipment. To rectify this situation, the engineer decided to design an audio pre-amplifier using an operational amplifier (op-amp) to boost the signal level.
The specifications for the pre-amplifier were clear. It needed to amplify the audio signal by a factor of 10, have an input impedance above 10...
The specifications for the pre-amplifier were clear. It needed to amplify the audio signal by a factor of 10, have an input impedance above 10...
231
Small-Signal Analysis of MOSFET Amplifiers
557
In small-signal analysis, a MOSFET transistor amplifier acts as a linear amplifier when operating in its saturation region. The gate-to-source voltage (VGS) of the MOSFET is the sum of the DC biasing voltage and the small time-varying input signal. This combination sets up the operating point and modulates the drain current (ID) that flows from the drain to the source. When a small AC signal is superimposed on the DC bias voltage at the gate, the instantaneous drain current comprises three...
557
Cascaded Op Amps
633
Operational amplifiers (op-amps) are versatile electronic components that can be interconnected in a cascade - one after another in a linear sequence. This cascading is possible due to their infinite input resistance and zero output resistance, allowing them to maintain their input-output relationships even when connected in series.
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
633
MOSFET Amplifiers
156
The MOSFET, when operating in its active region, functions as a voltage-controlled current source. In this region, the gate-to-source voltage controls the drain current. This principle underlies the operation of the transconductance MOSFET amplifier. The output current is directed through a load resistor to convert this amplifier into a voltage amplifier. The output voltage is then obtained by subtracting the voltage drop across the load resistance from the supply voltage. This process results...
156
Small-Signal Analysis of BJT Amplifiers
1.1K
Small signal analysis is a fundamental approach used in electronics to understand how a Bipolar Junction Transistor (BJT) amplifier processes signals. In the active region, the BJT is designed for linear amplification. The transistor's behavior under these conditions is governed by its instantaneous base-emitter voltage VBE, a sum of the DC bias VBE, and a small AC signal VBE, resulting in the collector current iC. Here, the collector current has a DC component and an AC component.
1.1K
Instrumentation Amplifier
517
An electrocardiography (ECG) machine is an essential piece of medical equipment used to monitor the electrical activity of the heart. It operates by detecting small electrical changes on the skin that result from the depolarization of the heart muscle during each heartbeat. However, these signals are in the microvolt range and can be easily overwhelmed by noise or interference.
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
517