对故障记录分析算法的研究,将其时间域波形与相域轨迹结合起来
1School of Electrical and Control Engineering, Liaoning Technical University, Huludao Liaoning, 125105, China.
Scientific reports
|February 23, 2024
概括
本研究引入了一种分析电力系统故障记录的新方法,通过将时间域电流波形转换为相域轨迹. 这种方法简化了故障分析和波形重制,以改善电力系统运行.
科学领域:
- 电气工程 电气工程
- 电力系统分析 分析 分析
背景情况:
- 电力系统故障会破坏运营和国家经济,需要精确的故障处理.
- 数字故障记录器捕获电量波形,对于分析系统干扰至关重要.
研究的目的:
- 开发和验证一个算法,用于重构断裂电流波形.
- 通过将时间域数据转换为相域轨迹来分析故障特征.
主要方法:
- 模拟的当前故障记录被分析.
- 波形从时间域转换为相域.
- 断层特征参数被提取并用于波形重制.
主要成果:
- 在重制和原始波形之间发现了高的相关系数.
- 拟议的算法在捕获故障特征方面表现出有效性.
结论:
- 开发的算法为电力系统故障记录分析提供了一种简单方便的方法.
- 调整后的波形可以用于改进电力系统功能.
更多相关视频
07:14Tracking Infiltration Front Depth Using Time-lapse Multi-offset Gathers Collected with Array Antenna Ground Penetrating Radar
Published on: May 1, 2018
7.8K
09:32Network Analysis of Foramen Ovale Electrode Recordings in Drug-resistant Temporal Lobe Epilepsy Patients
Published on: December 18, 2016
12.4K
相关概念视频
Fault Types
88
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
88
Power System Three-Phase Short Circuits
85
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
85
Graphical and Analytic Representation of Sinusoids
402
Analyzing two sinusoidal voltages with equal amplitude and period but different phases on an oscilloscope, an instrument used to display and analyze waveforms, involves a three-step process.
The first step is measuring the peak-to-peak value, which is twice the amplitude of the sinusoid. This provides information about the maximum voltage swing of the waveform.
Secondly, the period and angular frequency are determined. The period is the time taken for one complete cycle of the waveform, while...
The first step is measuring the peak-to-peak value, which is twice the amplitude of the sinusoid. This provides information about the maximum voltage swing of the waveform.
Secondly, the period and angular frequency are determined. The period is the time taken for one complete cycle of the waveform, while...
402
Bus Impedance Matrix
120
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
120
Discrete Fourier Transform
284
The Discrete Fourier Transform (DFT) is a fundamental tool in signal processing, extending the discrete-time Fourier transform by evaluating discrete signals at uniformly spaced frequency intervals. This transformation converts a finite sequence of time-domain samples into frequency components, each representing complex sinusoids ordered by frequency. The DFT translates these sequences into the frequency domain, effectively indicating the magnitude and phase of each frequency component present...
284
Three-Phase Short Circuit—Unloaded Synchronous Machine
143
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
143