在蛋白质食品加工过程中使用电场
Ricardo N Pereira1,2, Rui Rodrigues1,2, Zita Avelar1
1CEB-Centre of Biological Engineering, University of Minho, 4710-057 Braga, Portugal.
Foods (Basel, Switzerland)
|February 24, 2024
概括
电场处理为改变食品蛋白质特性提供了新的方法,影响了传统和替代来源. 本综述侧重于工业相关的电场技术及其对蛋白质结构和功能的影响.
科学领域:
- 食品科学与技术 食品科学与技术
- 生物物理学的生物物理.
- 材料科学 材料科学 材料科学
背景情况:
- 基于电场的技术为食品加工提供了独特的机会.
- 控制的散热 (欧米加热) 和电变量 (电穿孔) 可以改变食物的特性.
- 新兴的植物和微生物蛋白质来源需要先进的加工技术.
研究的目的:
- 审查用于食品应用的电场处理 (EFP) 技术.
- 探索EFP对蛋白质部分的结构和生物学影响.
- 将EFP对传统和替代蛋白质来源的影响置于背景中.
主要方法:
- 关于食品电场加工的科学文献的综述.
- 专注于工业上实施的EFP技术.
- 对热和非热电场对蛋白质的影响的分析.
主要成果:
- 包括欧姆加热和电穿孔在内的EFP可以改变食品蛋白的功能.
- 热和非热EFP都会影响蛋白质结构和生物特性.
- 该审查涵盖了广泛的蛋白质来源,包括新的蛋白质来源.
结论:
- 电场处理是增强食品蛋白质特性的一种有前途的技术.
- 了解EFP的影响对于优化食品产品开发至关重要.
- 对各种蛋白质来源的EFP应用进行进一步的研究是有必要的.
相关概念视频
Two-dimensional Gel Electrophoresis
6.0K
Two-dimensional gel electrophoresis is a high-resolution protein separation method first introduced by O' Farrell and Klose in 1975. This method involves protein separation by two dimensions, mass and charge, making it more accurate than one-dimensional gel electrophoresis.
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
6.0K
SDS-PAGE
28.0K
Gel electrophoresis is a method that separates biological macromolecules like nucleic acids or proteins by forcing them to pass through a gel matrix under an electric field.
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...
28.0K
Protein Denaturation
4.2K
The function of proteins depends on their native three-dimensional structure, which is dictated by the amino acid sequence of the specific protein. Folding of the polypeptide chain takes place under specific conditions that energetically favor the folded conformation. In contrast, protein denaturation occurs spontaneously under unfavorable conditions that disrupt the integrity of the folded conformation. Thus, the chemical and physical environment of a protein, such as significant changes in pH...
4.2K
Capillary Electrophoresis: Instrumentation
234
Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
234
Western Blotting
16.0K
Western blotting is an analytical technique for protein identification. It has various applications in immunology and medicine, including detecting diseases like bovine spongiform encephalopathy, mad cow disease, and human and feline immunodeficiency virus from biological samples.
The technique begins with separating proteins from the sample using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), followed by protein transfer, immunoblotting, and finally, protein detection.
The technique begins with separating proteins from the sample using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), followed by protein transfer, immunoblotting, and finally, protein detection.
16.0K
Electrochemical Gradient and Channel Proteins: An Overview
2.2K
An electrochemical gradient is a fundamental concept in biology and chemistry. It regulates the movement of ions across cell membranes. This movement is influenced by two factors:
The electrical gradient: The electrical gradient across cell membranes refers to the difference in electric charge between the inside and outside of a cell. This difference drives the movement of ions towards or away from the cells. For instance, if the inside of the cell is more negatively charged relative to...
The electrical gradient: The electrical gradient across cell membranes refers to the difference in electric charge between the inside and outside of a cell. This difference drives the movement of ions towards or away from the cells. For instance, if the inside of the cell is more negatively charged relative to...
2.2K


