在无线传感器网络中基于电力分割的中继的安全性和可靠性分析
Minh Tran1, Lam-Thanh Tu1, Bui Vu Minh2
1Communication and Signal Processing Research Group, Faculty of Electrical and Electronics Engineering, Ton Duc Thang University, Ho Chi Minh City 70000, Vietnam.
Sensors (Basel, Switzerland)
|February 24, 2024
概括
本研究分析了物联网网络中的权力分割 (PS) 继电安全性. 动态PS中继 (DPSR) 通过将故障概率降到最低,提供了优于静态PS中继 (SPSR) 的性能.
科学领域:
- * 无线通信网络无线通信网络
- * * 信息安全信息安全
- * 物联网 (IoT) 的互联网.
背景情况:
- *基于电力分割 (PS) 的继电对于物联网 (IoT) 网络至关重要.
- *安全性和可靠性是这些网络中最重要的关注点,特别是在存在干扰器的情况下.
研究的目的:
- * 调查物联网网络中基于PS的中继的安全性和可靠性.
- *分析和比较静态PS中继 (SPSR) 和动态PS中继 (DPSR) 方案的性能.
主要方法:
- *对于SPSR和DPSR方案的中断概率 (OP) 和拦截概率 (IP) 的推导.
- * 系统性能的数学建模和数值分析.
- *优化DPSR计划中的PS比率,以尽量减少OP.
主要成果:
- *中断概率 (OP) 和拦截概率 (IP) 呈现出与传输功率和源数相矛盾的趋势.
- * 动态PS中继 (DPSR) 方案表现出比静态PS中继 (SPSR) 方案优越的性能.
- * 数值结果验证了拟议的数学框架,并突出了依赖参数的性能趋势.
结论:
- * DPSR方案为物联网网络中基于PS的中继提供了增强的安全性和可靠性.
- *在DPSR中对PS比率进行最佳调整是提高网络性能的关键.
- * 了解OP和IP之间的权衡对于设计安全的物联网系统至关重要.
相关概念视频
Pilot and Numeric Relaying
86
Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
86
Distribution Reliability and Automation
107
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
107
Differential Relays
135
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
135
Directional Relays
113
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
113
Line Protection with Impedance Relays
81
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
81
Radial System Protection
95
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
95