使用超分辨率和TEM技术准备和成像专门的ER
Karen Bell1, Karl Oparka1, Kirsten Knox2
1Institute of Molecular Plant Sciences, School of Biological Sciences, University of Edinburgh, Edinburgh, UK.
Methods in molecular biology (Clifton, N.J.)
|February 27, 2024
概括
研究人员使用先进的显微镜技术开发了新的方法来可视化植物内 плазма网膜 (ER) 和其专业结构,元素网膜 (SER) 和脱管.
科学领域:
- 植物细胞生物学 植物细胞生物学
- 显微镜技术 显微镜技术
- 植物解剖学 植物解剖学
背景情况:
- 植物内质网膜 (ER) 形成特殊结构,如元素网膜 (SER) 和脱管.
- 由于光显微镜的分辨率限制和ER的脆弱性,对这些结构的成像具有挑战性.
研究的目的:
- 开发和描述用于可视化活细胞和固定组织中的植物ER结构的方法.
- 克服对研究SER和脱管的成像限制.
主要方法:
- 使用3D结构化照明显微镜 (3D-SIM) 进行活细胞成像.
- 开发了与3D-SIM和传输电子显微镜 (TEM) 兼容的浮膜组织的固定和准备协议.
主要成果:
- 在活植物细胞中使用3D-SIM.IM成功可视化了脱管.
- 通过3D-SIM和TEM实现了固定体组织中的体元素网膜 (SER) 的详细成像.
结论:
- 描述的方法显著提高了对脆弱植物ER结构的成像能力.
- 这些技术促进了SER和脱管的详细结构分析,推动了植物细胞生物学研究.
相关概念视频
Super-resolution Fluorescence Microscopy
7.0K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
7.0K
Cryo-electron Microscopy
3.3K
Conventional electron microscopy (EM) involves dehydration, fixation, and staining of biological samples, which distorts the native state of biological molecules and results in several artifacts. Also, the high-energy electron beam damages the sample and makes it difficult to obtain high-resolution images. These issues can be addressed using cryo-EM, which uses frozen samples and gentler electron beams. The technique was developed by Jacques Dubochet, Joachim Frank, and Richard Henderson, for...
3.3K
Preparation of Samples for Electron Microscopy
5.4K
To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...
5.4K
Electron Microscope Tomography and Single-particle Reconstruction
2.4K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.4K


