横孔互锁复合材料绝缘块的数值热评估和理论分析
Lei Shuai1,2, Jingshu Zhang1,2, Jianxin Song1,2
1Key Laboratory of Mechanics on Disaster and Environment in Western China, Ministry of Education of China, Lanzhou 730000, China.
Heliyon
|February 29, 2024
概括
这项研究数值分析了相互锁定的绝缘块,发现H形设计提供了优越的热性能. 降低材料的导热率,特别是在混凝土中,可以显著提高建筑墙壁的能源效率.
科学领域:
- 建筑科学 建筑科学
- 材料科学 材料科学 材料科学
- 热力工程是热力工程中的一个.
背景情况:
- 互锁复合材料绝缘块对于节能建筑设计至关重要.
- 了解它们的热性能是优化绝缘策略的关键.
- 现有的模型需要对不同的块配置和材料进行验证.
研究的目的:
- 为数值分析54个水平孔互锁复合材料绝缘块的热性能.
- 为区块热参数建立准确的预测模型.
- 调查块类型和材料对热效率的影响.
主要方法:
- 稳态热传递模型用于数值分析.
- 平行网络热阻模型用于参数预测.
- 对H形与十字形块的比较分析.
- 评估各种块材料的导热率.
主要成果:
- 与十字形隔热块相比,H形互锁隔热块表现出优越的热性能.
- 块材料的热导率降低显著改善了热性能.
- 降低混凝土的导热率产生了最实质性的性能提升.
- 模拟的导热值显示了与并行网络模型预测的高线性相关性 (R2 > 0.998).
结论:
- 可以开发H形互锁绝缘块的准确预测模型.
- 该研究为互锁隔热块墙的节能设计提供了宝贵的指导.
- 优化块材料特性对于最大限度地提高建筑的热效率至关重要.
相关概念视频
Thermal Insulation in Masonry Walls
124
In hot, dry climates, the thermal mass of masonry walls can be beneficial, absorbing heat during the day and releasing it at night, thereby stabilizing indoor temperatures. However, in most other climates, additional insulation is necessary to enhance thermal resistance.
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
124
Conduction, Convection and Radiation: Problem Solving
1.2K
There are three methods by which heat transfer can take place: conduction, convection, and radiation. Each method has unique and interesting characteristics, but all three have two things in common: they transfer heat solely because of a temperature difference; and the greater the temperature difference, the faster the heat transfer.
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
1.2K
Shear on the Horizontal Face of a Beam Element
173
To understand shear on the flat side of a prismatic beam element, consider the vertical and horizontal shearing forces, and the normal forces, acting on the element. The element's upper (U) and lower (L) sections, which are divided by the beam's neutral axis, are examined. The equilibrium of these forces is determined by applying the equilibrium equation, which helps identify the horizontal shearing force. This force is directly related to the bending moments and the cross-section's...
173
Composite Masonry Walls
1.2K
Composite masonry walls combine multiple wythes of the same or different masonry materials to create a unified structure. These walls feature wythes that are bonded together either through mortar-filled collar joints, grouted spaces, or more commonly, with rigid metal ties and reinforcements, with the use of masonry header units being rare. Metal ties are preferred because they effectively minimize water penetration, as these walls primarily absorb moisture and then release it into the...
1.2K
Masonry Cavity Walls
1.0K
Cavity walls feature a hollow space between the outer and inner wythes, connected only by corrosion-resistant metal ties. When water seeps through the outer wythe, it descends within this cavity, intercepted by flashing and eventually exiting through weep holes. To enhance moisture resistance, the inner wythe's cavity side often receives damp-proofing, doubling as an air barrier. The cavity can also house insulation to mitigate heat transfer.
Maintaining a clean cavity during construction...
Maintaining a clean cavity during construction...
1.0K
Masonry in Cold and Hot Weather Conditions
88
In cold weather, masonry construction requires specific precautions to ensure mortar does not freeze before curing, as this can significantly weaken its strength and watertightness. Mortar temperature should be maintained between 60°F and 80°F to support proper hydration and curing. Below 40°F, mortar water must be heated, but should not exceed 120°F as high temperatures can reduce mortar's compressive and bond strength.
Other key practices include keeping masonry units...
Other key practices include keeping masonry units...
88