研究建设"全链"快速响应系统的研究,以应对电力紧急情况
Su Zhang1, Xiaolu Liu1, Jingui Wang1
1College of Environment and Safety Engineering, Fuzhou University, Fuzhou, 350116, China.
Heliyon
|February 29, 2024
概括
本研究为电力公司引入了一种"1+N"应急响应系统,以改善电力应急管理. 开发的"全链"系统增强了应急响应能力,并为电力行业提供了一个标准化的模型.
科学领域:
- 电力系统工程 电力系统工程
- 应急管理 应急管理
- 可持续的发展 可持续的发展
背景情况:
- 不有效的电力应急响应系统阻碍了社会可持续发展.
- 紧急利益相关者之间不清楚的责任分配使灾害管理复杂化.
- 这是一个很棒的节目,这是一个很棒的节目.
- 在Fa-Fa中.
- 台风突出了提高电力部门应急准备能力的需要.
研究的目的:
- 解决在紧急情况下电力应急响应效率低下的问题.
- 澄清电力部门紧急主题之间的职责分配.
- 开发一个"全链"的电力紧急快速反应系统.
主要方法:
- 在一个县级城市供电公司内建立一个"1+N"两级紧急快速响应单位.
- 开发一个全面的"全链"系统,包括应急响应,协调和材料储备.
- 在"In-Fa"台风期间分析系统性能的案例研究.
主要成果:
- "1+N"系统显著提高了紧急作战能力.
- 观察到加强了灾难预防和减轻能力.
- 该系统展示了改进的紧急安全能力.
结论:
- 构建的"全链"电力紧急快速响应系统标准化了电力紧急响应.
- 该系统为更广泛的电力行业的应急准备提供了宝贵的参考.
- 这种方法通过改进电力部门的应急管理来加强社会弹性.
更多相关视频
相关概念视频
Reclosers and Fuses
105
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
105
Radial System Protection
95
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
95
Power System Three-Phase Short Circuits
84
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
84
Primary Distribution
103
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
103
Fast Decoupled and DC Powerflow
192
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
192
Overcurrent Relays
85
Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
85