A Bright NIR-II Fluorescence Probe for Vascular and Tumor Imaging
Published on: March 17, 2023
1.8K
在没有预期激发光的情况下进行NIR-II光成像
Aiyan Ji1,2, Hongyue Lou2, Jiafeng Li2
1Department of Pharmacy, School of Pharmacy, Fudan University Shanghai 201203 China zhaoweili@fudan.edu.cn.
Chemical science
|March 1, 2024
概括
研究人员使用一种新型染料开发了白色发光二极管 (LED) 激发的近红外II (NIR-II) 成像. 这种方法可以清晰可视化小瘤和血管,指导手术切除.
科学领域:
- 生物医学光学 生物医学光学
- 医疗成像医学成像
- 光成像技术 光成像技术
背景情况:
- 第二次近红外窗 (NIR-II) 成像通常使用激光二极管来激发.
- 由于缺乏合适的光学探头,阻碍了白光激发的NIR-II成像.
- 现有的方法,如氨酸绿 (ICG) 在激光照射下遭受显著的光灭.
研究的目的:
- 开发和评估多波长白发光二极管 (LED) 激发的NIR-II成像技术.
- 为了引入一种新的蓝移 NIR-II 染料,TPA-TQT,用于白光激发.
- 评估该系统对生物医学成像和图像引导手术的性能.
主要方法:
- 使用了一种新的蓝移NIR-II染料 (TPA-TQT) 与多波长白色LED.
- 将白色LED激发与单波长LED和传统激光激发进行比较.
- 评估了血管和淋巴毛细血管的成像分辨率.
- 评估了系统在监测后肢缺血-再输和淋巴炎炎症模型中的有效性.
- 在携带瘤的小鼠中进行了白色LED激发的NIR-II光成像引导手术 (FIGS).
主要成果:
- 与808nm激光照射相比,白色LED系统显示出最小的光灭.
- 多波长LED激发提供了比单波长LED低的背景噪声.
- 实现了高分辨率的图像,识别了血管 (103微米) 和淋巴毛细血管 (129.8微米).
- 该系统成功地监测了诸如缺血-再输和淋巴炎症等生理过程.
- 白色LED激发的NIR-II图清楚地划出了小转移性瘤病变 (∼350微米),并指导了手术切除.
结论:
- 基于多波长白色LED的NIR-II成像是一种可行的激光激发替代方案.
- 这种新的系统提供了更好的染料稳定性和成像性能.
- 这项技术在精确的瘤划分和图像引导手术方面具有显著的潜力.
- 白色LED激发的NIR-II成像对各种生物医学应用具有前景.
相关概念视频
Total Internal Reflection Fluorescence Microscopy
5.7K
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
5.7K
Super-resolution Fluorescence Microscopy
7.0K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
7.0K
Fluorescence and Phosphorescence: Instrumentation
592
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
592
Immunofluorescence Microscopy
10.4K
A fluorescence microscope uses fluorescent chromophores called fluorochromes, which can absorb energy from a light source and then emit this energy as visible light. Fluorochromes include naturally fluorescent substances (such as chlorophylls) and fluorescent stains that are added to the specimen to create contrast. Dyes such as Texas red and FITC are examples of fluorochromes. Other examples include the nucleic acid dyes 4’,6’-diamidino-2-phenylindole (DAPI), and acridine orange.