显露壁画的微气候和花朵之间的关系以及后来的保护策略
Shiqiang Fang1, Wenjing Hu2, Qian Li3
1Centre for the Protection of Cultural Property, Ningbo University of Finance & Economics, Ningbo 315175, PR China; Department of Cultural Heritage and Museology, Zhejiang University, Hangzhou 310028, PR China.
The Science of the total environment
|March 1, 2024
概括
发现的古代壁画由于湿度和二氧化硫等环境因素而迅速恶化,形成有害的硫酸. 不恰当的修复干预会使保存变得更糟,强调需要控制环境来保护暴露的艺术品.
科学领域:
- 艺术保护科学 艺术保护科学
- 材料科学 是一种材料科学.
- 保护文化遗产 保护文化遗产
背景情况:
- 古代壁画经常被隐藏,最近的重点是对非破坏性诊断和覆盖去除.
- 有限的研究已经解决了覆盖移除对露面壁画长期保存的影响.
研究的目的:
- 以石王子宫作为案例研究,分析导致露面壁画迅速恶化的因素.
- 调查环境条件和材料相互作用在曝光后壁画退化中的作用.
主要方法:
- 对壁画本体学和构成的分析.
- 对保护环境的调查,包括湿度和大气污染物.
- 模拟实验以复制恶化过程.
主要成果:
- 壁画表面的碳酸石灰颗粒在潮湿的条件下与二氧化硫反应,形成硫酸.
- 硫酸的吸湿性增加了表面的湿度,加速了二氧化硫的进一步吸收和硫酸盐/水分的损害.
- 不准确的干预,如不透气的涂料和有机涂料,加剧了壁画的恶化.
结论:
- 保护暴露的隐藏壁画需要严格控制环境湿度和酸气水平.
- 了解物质与环境的相互作用对于发现古代艺术品的有效保护策略至关重要.
相关概念视频
Efflorescence in Masonry
82
Efflorescence in masonry walls appears as a fluffy crystalline powder, often white, resulting from water-soluble salts within the masonry or mortar. When water penetrates the masonry, it dissolves these salts and brings them to the surface, where they are deposited upon evaporation of water.
While initial efflorescence is common post-construction and can be cleaned with water and a brush, in certain instances, efflorescence can reappear and gradually diminish over time as salts are leached out...
While initial efflorescence is common post-construction and can be cleaned with water and a brush, in certain instances, efflorescence can reappear and gradually diminish over time as salts are leached out...
82
Masonry in Cold and Hot Weather Conditions
88
In cold weather, masonry construction requires specific precautions to ensure mortar does not freeze before curing, as this can significantly weaken its strength and watertightness. Mortar temperature should be maintained between 60°F and 80°F to support proper hydration and curing. Below 40°F, mortar water must be heated, but should not exceed 120°F as high temperatures can reduce mortar's compressive and bond strength.
Other key practices include keeping masonry units...
Other key practices include keeping masonry units...
88
Mortar Joint Deterioration in Masonry
117
Mortar joint deterioration is a significant concern in masonry structures, with water accumulation in the joints leading to damage from freeze-thaw cycles. The repeated expansion of water during freezing and its melting during thawing develop and propagate cracks in the masonry joints. Eventually, this leads to the spalling of mortar from the joints, loosening masonry units and weakening the structure. The deteriorated mortar joints are also vulnerable to moisture intrusion into the walls.
The...
The...
117
Cavity Drainage and Flashings in Masonry walls
81
Typically, a cavity wall consists of two wythes separated by a gap of at least 2 inches, which may contain insulation while still maintaining a minimum clear space of 1 inch to facilitate adequate drainage. Advanced methods like the insertion of a continuous drainage mat can further reduce this space while ensuring effective moisture expulsion.
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
81
Thermal Insulation in Masonry Walls
124
In hot, dry climates, the thermal mass of masonry walls can be beneficial, absorbing heat during the day and releasing it at night, thereby stabilizing indoor temperatures. However, in most other climates, additional insulation is necessary to enhance thermal resistance.
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
124
Frost Action on Concrete
98
Concrete structures in cold climates, such as those along roadsides, can retain moisture. This moisture makes them susceptible to frost-related damage when temperatures fall below freezing. Adding moisture worsens the damage during temperature fluctuations, leading to repeated freezing and thawing. De-icing salts, spread over these structures to melt ice, add to the freeze-thaw cycle, and draw even more moisture into the concrete.
This freeze-thaw cycle primarily causes surface scaling, where...
This freeze-thaw cycle primarily causes surface scaling, where...
98