节奏部位对P波参数的影响:对右心房附属体和巴克曼束的患者内部比较
Natasha A Vedage1, Edmond M Cronin1
1Section of Cardiology, Department of Medicine, Lewis Katz School of Medicine at Temple University, Philadelphia, PA, United States of America.
Journal of electrocardiology
|March 3, 2024
概括
巴克曼捆绑节奏 (BBp) 与右心房附属体节奏 (RAAp) 相比,显著改善了P波参数. BBp缩短P波持续时间和PR间隔,同时增加P波电压,这表明血液动力学的好处.
科学领域:
- 心脏病学 心脏病学
- 电子生理学 电子生理学
- 医疗器械 医疗器械
背景情况:
- 传统的右心房附属体节奏 (RAAp) 与由于电机动心房延迟而导致的不良结果有关.
- 巴赫曼捆绑节奏 (BBp) 提供了一个更生理性的激活模式.
- 关于节奏点如何影响P波参数的数据有限.
研究的目的:
- 为了比较P波在鼻节律,RAAp和BBp期间的参数.
- 分析节拍部位对心房激活特征的影响.
主要方法:
- 从21名接受心房植入的患者的手术内心电图的回顾性分析.
- 7P波参数的比较 (持续时间,电压,面积,PR间隔,PR段,PTFV1,轴) 在鼻腔节律,RAAp和BBp之间.
主要成果:
- 与RAAp (144.0 ms) 和鼻腔节律 (134.5 ms) 相比,BBp显著减少了P波持续时间 (98.0 ms).
- BBp导致II中最大的P波电压 (0.16 mV),高于RAAp (0.08 mV) 和鼻腔节律 (0.11 mV).
- 与RAAp (204.0 ms) 和鼻腔节律 (185.0 ms) 相比,BBp显著缩短了PR间隔 (163.0 ms).
结论:
- 巴克曼捆绑节奏显示了对节奏P波参数的有利影响.
- BBp导致P波持续时间缩短,P波电压增加,PR段延长.
- 这些改进表明BBp与传统RAAp相比具有潜在的血液动力学优势.
更多相关视频
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
10.5K
10:39Rat Model of Right-Sided Cardiac Remodeling and Arrhythmia Using Pulmonary Artery Banding
Published on: August 30, 2024
643
相关概念视频
Conduction System of the Heart
6.7K
Autorhythmicity is a term that refers to the heart's inherent ability to generate electrical signals and instigate muscle contractions. This self-regulating conduction system within the heart consists of two key components: the pacemaker cells and specialized conducting cells.
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
6.7K
Electrophysiology of Normal Cardiac Rhythm
4.2K
The normal cardiac rhythm is a synchronized electrical activity that facilitates the regular and coordinated contraction of the heart muscle. This process is essential for efficient blood circulation throughout the body. The fundamental elements involved in establishing and maintaining this rhythm include the unique electrical properties of cardiac muscle cells, the sinoatrial (SA) node's pacemaker function, the specialized conducting system, and the ionic mechanisms underlying each phase...
4.2K
The Cardiac Cycle
88.0K
The heart beats rhythmically in a sequence called the cardiac cycle—a rapid coordination of contraction (systole) and relaxation (diastole).
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...
88.0K
Correlation between ECG and Cardiac Cycle
5.2K
The electrical signals recorded on an electrocardiogram (ECG) occur before the mechanical processes of contraction and relaxation during the cardiac cycle.
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
5.2K
Assessment of apical radial pulse
742
Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
742