过电缆的设计具有缺陷的导体层
Yunan Han1, Shuangqing Xiong2, Chunyue Cheng3
1Department of the College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China. hanyn@mail.buct.edu.cn.
Scientific reports
|March 3, 2024
概括
本研究介绍了一种具有缺陷导体层 (DCL) 的创新过电缆,以解决电磁兼容性 (EMC) 问题. 新设计有效地抑制特定频段的电磁干扰,提供可调节的过功能.
科学领域:
- 电气工程 电气工程
- 电磁学 电磁学 电磁学 电磁学
- 材料科学 材料科学 材料科学
背景情况:
- 由于缺乏分布式过,传统的电缆是电磁兼容性 (EMC) 问题的主要合路径.
- 有效的EMC解决方案对于工业应用中相互连接的电气设备的可靠运行至关重要.
研究的目的:
- 设计和验证一条具有集成分布式过能力的创新过电缆.
- 解决电磁干扰 (EMI) 问题,开发一条沿其长度抑制信号的电缆.
主要方法:
- 开发一条包含被缺陷导体层 (DCL) 覆盖的绝缘电线的过电缆.
- 利用微波网络分析,将过电缆建成一个双端口网络,用于分析级联特征.
- 使用灵活的印刷电路板 (FPCB) 制造了一条多止带过电缆,配备了牙形DCL,并将电容器安装在同轴电缆上.
主要成果:
- 模拟和测量结果证实了在指定停止带内有效抑制电磁干扰.
- 过性能被证明是通过改变安装组件的电容值来调节的.
- 拟议的过电缆设计实现了沿其轴分布式过的优势.
结论:
- 新的过电缆设计通过提供分布式过来有效地减轻EMC问题.
- 开发的过电缆为抑制电磁干扰提供了可调节的解决方案,可适应各种应用需求.
相关概念视频
Transmission Line Design Considerations
135
Aluminum has become the material of choice for overhead transmission lines, surpassing copper due to its abundance and cost-effectiveness. The most prevalent type is the aluminum conductor, steel-reinforced (ACSR), which combines aluminum strands around a steel core. Other variants include all-aluminum conductors (AAC), all-aluminum alloy conductors (AAAC), aluminum conductor alloy-reinforced (ACAR), and aluminum-clad steel conductors. Advanced designs, such as aluminum conductors with steel...
135
Energy Stored In A Coaxial Cable
1.5K
A coaxial cable consists of a central copper conductor used for transmitting signals, followed by an insulator shield, a metallic braided mesh that prevents signal interference, and a plastic layer that encases the entire assembly.
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic...
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic...
1.5K
Design Example
327
The innovation of touch-tone telephony revolutionized the telecommunications industry by replacing the traditional rotary dial with a dual-tone multi-frequency (DTMF) signaling system. This system uses a matrix-style keypad with buttons arranged in four rows and three columns, creating 12 distinct signals each assigned to a pair of frequencies. Each button press results in a simultaneous generation of two sinusoidal tones – one from a low-frequency group (697 to 941 Hz) and one from a...
327
Lossy Lines and Overvoltages
88
Transmission-line series resistance and shunt conductance cause three primary effects: attenuation, distortion, and power losses.
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
88
Boundary Conditions: Lossless Lines
93
Consider a single-phase, two-wire, lossless transmission line terminated by an impedance at the receiving end and a source with Thevenin voltage and impedance at the sending end. The line, with length, has a surge impedance and wave velocity determined by the line's inductance and capacitance.
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
93
Reducing Line Loss
152
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
152