Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

8.0K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
8.0K

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

On the applicability of x-ray strain imaging using the edge illumination technique in biomedical applications.

Journal of physics D: Applied physics·2025
Same author

T staging esophageal tumors with x rays.

Optica·2024
Same author

On the equivalence of the X-ray scattering retrieval with beam tracking and analyser-based imaging using a synchrotron source.

Journal of physics D: Applied physics·2023
Same author

A laboratory-based beam tracking x-ray imaging method achieving two-dimensional phase sensitivity and isotropic resolution with unidirectional undersampling.

Scientific reports·2023
Same author

Test and optimisation of a multi-modal phase-based x-ray microscope for soft tissue imaging.

Proceedings of SPIE--the International Society for Optical Engineering·2022
Same author

Cycloidal-spiral sampling for three-modal x-ray CT flyscans with two-dimensional phase sensitivity.

Scientific reports·2022

相关实验视频

Updated: Jul 1, 2025

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

8.5K

为优化固定长度微CT系统的框架,用于基于传播的相对比成像.

G Lioliou, I Buchanan, A Astolfo

    Optics express
    |March 5, 2024
    PubMed
    概括
    此摘要是机器生成的。

    这项研究优化了实验室X射线成像系统用于相对比计算断层扫描 (CT). 优化的系统使用易于获得的组件实现了生物样本的图像质量提高.

    更多相关视频

    Strategies for Optimization of Cryogenic Electron Tomography Data Acquisition
    08:16

    Strategies for Optimization of Cryogenic Electron Tomography Data Acquisition

    Published on: March 19, 2021

    4.5K
    Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages
    08:46

    Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages

    Published on: April 13, 2016

    10.1K

    相关实验视频

    Last Updated: Jul 1, 2025

    Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
    06:25

    Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

    Published on: February 12, 2014

    8.5K
    Strategies for Optimization of Cryogenic Electron Tomography Data Acquisition
    08:16

    Strategies for Optimization of Cryogenic Electron Tomography Data Acquisition

    Published on: March 19, 2021

    4.5K
    Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages
    08:46

    Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages

    Published on: April 13, 2016

    10.1K

    科学领域:

    • 医疗成像医学成像
    • 物理 物理学 物理
    • 生物医学工程 生物医学工程

    背景情况:

    • 微计算机断层扫描 (micro-CT) 系统对于高分辨率成像至关重要.
    • 基于扩散的相对比成像技术比传统的基于吸收的成像方法具有更高的灵敏度.
    • 优化实验室X射线系统是提高图像质量和诊断能力的关键.

    研究的目的:

    • 研究和优化实验室X射线成像系统,用于基于单距离传播的相对比成像和计算机断层扫描 (CT).
    • 在固定长度设置中使用广泛可用的组件来证明显著的图像质量改进.
    • 通过与理论模型和波光学模拟进行比较来验证系统性能.

    主要方法:

    • 配置了一个实验室X射线成像系统,其源到探测器距离固定 (∼90厘米).
    • 在不同的X射线源设置和距离下,2D和3D成像PTFE线,以表征边缘对比度和空间分辨率.
    • 使用优化参数获得组织工程食道支架和大鼠心脏的计算机断层扫描 (CT) 扫描.

    主要成果:

    • 边缘对比度和空间分辨率的实验结果与理论模型和波光学模拟有很好的一致性.
    • 样本位置和X射线源参数的优化导致了更好的图像质量.
    • 生物样本的CT扫描成功地证明了该系统在详细成像方面的潜力.

    结论:

    • 基于传播的相对比成像参数的适当优化对于提高微型CT系统中的图像质量至关重要.
    • 在固定长度柜中使用标准组件可以实现显著的图像质量改进.
    • 优化的实验室X射线系统显示了对生物样本先进成像的前景.