一个灵活的多式脉冲传感器用于可穿戴的连续血压监测
Shuo Tian1, Liangqi Wang1, Rong Zhu1
1State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, 100084, China. zr_gloria@mail.tsinghua.edu.cn.
Materials horizons
|March 5, 2024
概括
一个新的灵活传感器使用皮肤精确测量了手腕脉冲波.
科学领域:
- 生物医学工程 生物医学工程
- 可穿戴技术可穿戴技术
- 心血管监测 心血管监测
背景情况:
- 无袖手腕脉冲监测对于早期发现心血管疾病至关重要.
- 辐射脉冲波形测量是具有挑战性的,因为信号的变化和文物.
- 穿戴压力和皮肤温度的变化会导致血压估计中的错误.
研究的目的:
- 开发一种灵活的多感应脉冲传感器,用于高准确度的辐射动脉脉冲波测量.
- 为了提高无袖血压监测的准确性和防伪性能.
- 为了实现精确的临床诊断和预防心血管疾病.
主要方法:
- 利用了人体皮肤和薄膜热敏电阻的自然压热传导.
- 集成的同时检测脉冲波形,皮肤温度和佩戴压力.
- 采用多层感知子用于特征融合和血压估计.
主要成果:
- 实现了高准确度脉冲测量,具有广泛的压力范围 (228.2 kPa) 和低检测极限 (4 Pa).
- 显示出出色的线性 (R2 = 0.999),低歇斯底里 (2.45%) 和快速响应 (88 ms).
- 成功抵制文物效应并准确估计血压,具有良好的概括性.
结论:
- 灵活的多感应传感器提供准确可靠的无袖血压监测.
- 集成的脉冲,压力和温度传感可以提高反物体性能.
- 这项技术有望用于非侵入性心血管健康评估和疾病预防.
更多相关视频
相关概念视频
Equipments Used To Measure Blood Pressure
969
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
969
Pulse rhythm
797
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
797
Special considerations while measuring blood pressure
722
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
722
Sites for measruring blood pressure
1.7K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.7K
Assessment of blood pressure in brachial artery(one-step method)
587
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
587
Assessment of blood pressure in brachial artery(two-step method)
706
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
706