使用超声波监测平衡
Shonit Nair Sharma1,2, Yuhan Lee1,3
1Department of Anesthesiology, Perioperative and Pain Medicine, Center for Accelerated Medical Innovation, and Center for Nanomedicine, Brigham and Women's Hospital, Boston, MA, USA.
概括
一个新的植入物可以在手术后方便地监测深层组织的变化. 这项创新有助于持续观察患者,及早发现术后并发症.
科学领域:
- 生物医学工程
- 外科创新
- 医疗设备技术
背景情况:
- 手术后对深层组织的监测对于检测并发症至关重要.
- 目前的监测方法通常需要临床访问,限制持续观察.
- 需要在家中找到可用的解决方案来追踪组织的愈合和变化.
研究的目的:
- 引入一种新型的可植入装置,用于远程监测深层组织的变化.
- 评估使用这种植入物进行术后护理的可行性.
- 通过持续监测,探索早期发现手术部位并发症的可能性.
主要方法:
- 开发一种微创植入式传感器.
- 传感器与无线数据传输系统的集成.
- 验证植入物检测深层组织相关生理变化的能力.
主要成果:
- 植入物成功监测了手术后模拟环境中的深层组织变化.
- 植入器的数据传输可靠,使得远程评估成为可能.
- 该装置显示了识别组织变化的关键指标的潜力.
结论:
- 一种可植入的装置为在家中持续监测手术后深层组织变化提供了有前途的方法.
- 这项技术可以促进患者的康复, 及时介入并发症.
- 需要进一步的临床研究来验证这种监测系统的有效性和安全性.
相关概念视频
Ultrasonography
4.5K
Ultrasonography is an imaging technique that uses high-frequency sound waves to visualize the body's internal structures. It is a non-invasive and safe procedure that does not involve the use of ionizing radiation, making it widely used in various medical fields. Ultrasonography is used to study heart function, blood flow in the neck or extremities, certain conditions such as gallbladder disease, and fetal growth and development.
During an ultrasonography procedure, a handheld device called...
During an ultrasonography procedure, a handheld device called...
4.5K
Assessing Blood pressure using a doppler ultrasound
1.3K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.3K
Ultrasound I: Abdominal Ultrasonography
220
Introduction:
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
220
Ultrasound II: Endoscopic Ultrasound and FibroScan
105
Endoscopic Ultrasound (EUS) and FibroScan are valuable diagnostic tools in gastroenterology and hepatology, each with specific applications and techniques.
Endoscopic Ultrasound (EUS):
Endoscopic Ultrasound (EUS):
105
What is Homeostasis?
37.5K
Maintaining homeostasis requires that the body continuously maintain its internal conditions. Each physiological condition has a particular set point, from body temperature to blood pressure to levels of certain nutrients. A set point is the physiological value around which the normal range fluctuates. A normal range is a restricted set of values that is optimally healthful and stable. For example, the set point for normal human body temperature is approximately 37°C (98.6°F).
37.5K
Equipments Used To Measure Blood Pressure
969
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
969