Doppler Optical Coherence Tomography of Retinal Circulation
Published on: September 18, 2012
通过Cirrus和Spectralis光学一致性断层扫描评估的超传输缺陷的面对面和体积测量比较
Jiwon Baek1, Maryam Ashrafkhorasani2, Alireza Mahmoudi3
1From the Doheny Eye Institute (J.B., M.A., A.M., M.G.N., G.C., S.R.S.), Pasadena, California, USA; Department of Ophthalmology, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea (J.B.), Bucheon, Gyeonggi-do, South Korea; Department of Ophthalmology, College of Medicine, The Catholic University of Korea (J.B.), Seoul, South Korea; Department of Ophthalmology, David Geffen School of Medicine at UCLA (J.B., A.M., G.C., S.R.S.), Los Angeles, California, USA.
光学连贯断层扫描 (OCT) 设备在干燥的与年龄相关的黄斑变性 (AMD) 中显示了可比的3D超传输缺陷 (HTD) 测量. 面对面的HTD图像可视化可以通过 Spectralis OCT 的处理来改进.
科学领域:
- 眼科医生 眼科 眼科
- 医疗成像医学成像
- 视网膜疾病 视网膜疾病
背景情况:
- 超传播缺陷 (HTD) 是干燥与年龄相关的黄斑变性 (AMD) 的特征发现.
- 评估HTD对于了解AMD进展和评估治疗疗效至关重要.
- 不同的光连贯断层扫描 (OCT) 设备在成像能力上可能存在差异.
研究的目的:
- 为了比较Spectralis和Cirrus OCT设备之间的HTDs的面部和三维 (3D) 属性.
- 评估这些OCT设备的可互换性,用于在干燥的AMD中进行HTD评估.
主要方法:
- 一项比较诊断评估研究包括来自阿米什眼睛研究队列的30只患有干燥AMD的眼睛.
- 使用 Spectralis 和 Cirrus OCT 设备获得了密集的 OCT 黄斑体积扫描.
- 手动标记HTD区域,并重建3D卷和面部图像以进行比较.
主要成果:
- 对于Cirrus OCT (P < .01),面部图像的质量得分较高,但随着预处理,Spectralis图像的质量得到了改善.
- 设备之间在2D面积 (P = .478),HTD的数量,体积或表面积方面没有发现显著差异 (所有P ≥ .090).
- HTDs的规范信号强度也显示设备之间没有差异 (P = .861).
结论:
- 通过图像处理技术,可以增强Spectralis OCT面部图像上的HTD的可视化.
- 三维HTD参数的等价性表明,Spectralis和Cirrus OCT设备可以互换,用于评估干性AMD中的这些病变.
更多相关视频
12:22Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
Published on: August 4, 2018
06:15Author Spotlight: Anterior HR-OCT as a Non-Invasive Tool for Characterizing Ocular Surface Squamous Neoplasia
Published on: August 9, 2024
相关概念视频
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography