混合多输入接收器线路纵向保护方案基于电压波形综合距离相似性
Shuping Gao1,2, Xiaofang Li1,2, Guobing Song3
1Department of Electrical and Control Engineering, Xi'an University of Science and Technology, Xi'an 710054, China.
Sensors (Basel, Switzerland)
|March 13, 2024
概括
一种新的交流/直流互连保护方法使用电压波形相似性来准确地定位故障. 这种方法增强了对干扰和数据问题的稳定性.
科学领域:
- 电气工程 电气工程
- 电力系统 电力系统
背景情况:
- 交流/直流电源合影响了交流保护和电网稳定性.
- 现有的方法在干扰和数据异步方面扎.
研究的目的:
- 为交流/直流互连系统提出一种新的纵向保护方法.
- 为了提高故障位置的准确性和系统可靠性.
主要方法:
- 计算参考电压和优化波形适配.
- 使用欧几里德的动态时间曲线 (DTW) 距离和重法来计算相似性.
- 基于全面距离相似性的断层位置.
主要成果:
- 拟议的方法准确区分内部和外部故障.
- 在过渡阻力和噪声方面表现出卓越的性能.
- 缓解数据异步问题,提高速度和可靠性.
结论:
- 新的保护方案有效地解决了AC/DC互连方面的挑战.
- 与现有方法相比,提供了增强的弹性和性能.
更多相关视频
07:43A Simple Approach to Perform TEER Measurements Using a Self-Made Volt-Amperemeter with Programmable Output Frequency
Published on: October 5, 2019
21.9K
07:14Tracking Infiltration Front Depth Using Time-lapse Multi-offset Gathers Collected with Array Antenna Ground Penetrating Radar
Published on: May 1, 2018
7.8K
相关概念视频
Line Protection with Impedance Relays
79
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
79
Differential Relays
135
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
135
Radial System Protection
95
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
95
Boundary Conditions: Lossless Lines
93
Consider a single-phase, two-wire, lossless transmission line terminated by an impedance at the receiving end and a source with Thevenin voltage and impedance at the sending end. The line, with length, has a surge impedance and wave velocity determined by the line's inductance and capacitance.
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
93
Power System Three-Phase Short Circuits
84
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
84
Zones of Protection
168
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
168