肺动脉高血压患者的脉冲振荡计:一项探索性研究
Helena Jannuzzi Villas Bôas1, Ilma Aparecida Paschoal1, Mônica Corso Pereira1
1Departamento de Medicina Interna, Universidade de Campinas (UNICAMP), Campinas, SP, Brazil.
Clinics (Sao Paulo, Brazil)
|March 15, 2024
概括
脉冲振荡计 (IOS) 显示,异常性肺动脉高血压 (IPAH) 患者的呼吸阻力和反应能力增加. 这些发现与传统的螺旋计相对应,突出显示IOS是评估小气道功能在IPAH的有价值工具.
科学领域:
- 肺部医学 肺部医学
- 呼吸系统生理学 呼吸系统生理学
背景情况:
- 周围气道异常在肺动脉高血压 (PAH) 中越来越多地被认可.
- 脉冲振荡计 (IOS) 提供了一种非侵入性方法,通过测量呼吸系统阻抗 (阻力和反应率) 来评估小气道功能.
研究的目的:
- 用IOS在患有异常性PAH (IPAH) 的患者中评估呼吸阻力 (R) 和反应力 (X).
- 在IPAH患者中确定IOS参数和标准螺旋计测量结果之间的相关性.
主要方法:
- 在13名IPAH患者和11名健康对照组中进行了IOS和螺旋计.
- 关键的IOS变量包括R5,R20,R5-R20,AX (反应区域) 和Fres (共振频率).
- 统计分析包括组间的比较和IOS与螺旋计度量之间的相关性分析.
主要成果:
- 与健康对照组相比,IPAH患者的FVC,FEV1和FEF25-75显著降低.
- IOS在IPAH患者中显示出较低的潮体积和较高的AX,其中53.8%显示R5-R20升高.
- 在多个IOS变量 (X5,AX,R5-R20,Fres,R5,R20) 和螺旋计参数 (FVC,FEV1,FEF25-75) 之间观察到显著的相关性.
结论:
- IOS在IPAH患者的小气道中显示出迹象表明抵抗和反应能力增加的变化.
- IOS参数与螺旋计有很好的相关性,这表明它作为评估IPAH中外围气道参与的补充工具的实用性.
相关概念视频
Measurement of Blood Pressure
924
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
924
Pulse
510
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
510
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
208
Oxygen therapy has emerged as a significant tool in enhancing the quality of life for patients suffering from pulmonary arterial hypertension (PAH). While this therapy has principally been studied on patients with significant hypoxemia, this therapeutic approach helps prevent potential organ damage and can be administered in the comfort of one's home.
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
208
Sites for measruring blood pressure
1.7K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.7K
Pulse Oximetry
328
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
328
Equipments Used To Measure Blood Pressure
967
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
967