巧合质谱研究了由70 eV电子冲击对二烯的双电离
Peter J M van der Burgt1, Marcin L Gradziel1
1Department of Experimental Physics, National University of Ireland Maynooth, Maynooth, Co, Kildare, Ireland. peter.vanderburgt@mu.ie.
Physical chemistry chemical physics : PCCP
|March 21, 2024
概括
电子对烯分子的影响导致碎片化,揭示了复杂的解离路径. 双重电离会导致多个碎片,表明了重要的键断裂.
科学领域:
- 物理化学 物理化学
- 化学物理 化学物理
- 分子物理学 分子物理学
背景情况:
- 二烯是一种具有明确结构的多环芳化合物.
- 了解分子碎片化对于各种领域至关重要,包括天体化学和材料科学.
研究的目的:
- 为了研究电子冲击下的烯分子的碎片化模式.
- 为了分析由双电离产生的一致碎片.
主要方法:
- 采用了巧合质谱法.
- 一个反射子飞行时间质谱仪被用于离子选择.
- 现场可编程的门阵列促进了精确的定时和检测.
主要成果:
- 在70 eV的电子冲击中诱导了烯的碎片化.
- 双电离导致了突出的碎片,产生了两个单电离碎片.
- 几条碎片化路径产生了具有四个或更多碳原子的离子,需要至少三次C-C键断裂.
- 碎片离子表现出高达几 eV的动能.
结论:
- 这项研究阐明了双电离后的二烯复杂解离动态.
- 显著的C-C键裂变发生,导致大量的分子碎片化.
更多相关视频
相关概念视频
Chemical Ionization (CI) Mass Spectrometry
742
The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
742
Mass Spectrometry: Aromatic Compound Fragmentation
1.7K
Upon ionization, aromatic compounds generate a molecular ion that is observed as a prominent peak in their mass spectra. For example, the molecular ion peak for benzene appears at a mass-to-charge ratio of 78, while toluene is observed at a mass-to-charge ratio of 92. The molecular ion benzene is highly stable and does not readily undergo further fragmentation due to the significant amount of energy required to disrupt the aromatic stability of the benzene ring. In contrast, the molecular ion...
1.7K
Electrospray Ionization (ESI) Mass Spectrometry
809
Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
809
Mass Spectrometry: Complex Analysis
765
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
765
Mass Spectrometry: Overview
5.1K
Mass spectrometry is an analytical technique used to determine the molecular mass and molecular formula of a compound. The basic principle of mass spectrometry is to generate ions from the analyte molecule and measure these ion abundances against their molecular mass. One common type of ionization, known as electrospray ionization or EI, bombards the analyte molecules in the gas phase with high-energy electron beams. The electron beams displace an electron from the molecule and leave...
5.1K
Mass Spectrum: Interpretation
1.2K
An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a low-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.
To...
To...
1.2K