牙灌剂对树脂凝固协议中的推出键强度的影响 对于内牙治疗牙中的纤维柱:一个体外研究
Sandra García-Varela1, João Carlos Ramos2, María José Ginzo-Villamayor1
1Faculty of Dentistry, University of Santiago de Compostela, Entrerríos Street, No. 1, 15705 Santiago de Compostela, Spain.
Materials (Basel, Switzerland)
|March 28, 2024
概括
二 (NaOCl) 灌剂显著降低了纤维后树脂结合强度,特别是当与通用结合剂相结合时. 其他灌剂和粘合剂系统对粘合强度没有显著影响.
科学领域:
- 牙科材料科学 牙科材料科学
- 牙周内科医院 牙周内科医院 牙周内科医院
- 粘合式牙科 粘合式牙科
背景情况:
- 纤维后固对于恢复内牙治疗的牙至关重要.
- 内牙灌剂和粘合系统之间的相互作用会影响粘合物的耐用性.
- 了解这些相互作用对于可预测的临床结果至关重要.
研究的目的:
- 为了评估常见的内牙灌剂对纤维柱的树脂结合强度的影响.
- 为了比较不同粘合剂系统 (蚀刻和冲洗,自蚀刻,通用) 对粘合强度的影响.
- 为了确定灌剂和粘合剂之间的潜在不兼容性.
主要方法:
- 144颗人类牙接受了内牙治疗,分为12组.
- 这些组根据灌剂 (蒸水,EDTA,NaOCl,) 和粘合剂系统而有所不同.
- 进行了推出键强度测试和扫描电子显微镜 (SEM).
主要成果:
- 与其他灌剂相比,二 (5%) 显著降低了推出键强度.
- 5%的NaOCl和一种通用结合剂 (ClearfilTM Universal Bond) 的组合显著降低了结合力的强度.
- 粘合剂协议和后空间区域没有显著影响结合力的强度.
结论:
- 二化灌对纤维后树脂结合强度产生负面影响.
- 临床医生在使用NaOCl与纤维后固的通用粘合剂时应谨慎.
- 对灌剂-粘合剂相互作用的进一步研究是有必要的,以优化凝固协议.
相关概念视频
Bonding and Strength of Aggregate
152
The bond between aggregate particles and the cement matrix is significantly influenced by the shape and surface texture of the aggregates. High-strength concretes benefit from a rougher texture, which leads to stronger bonding due to greater adhesion. Angular aggregates with larger surface areas also enhance this bond. The bonding quality, however, is complex to assess as no universally accepted test exists. Good bonding is indicated when a crushed concrete specimen shows some aggregate...
152
Strength of Cement
133
Strength tests for cement are not performed directly on neat cement paste due to difficulty in obtaining consistent, reliable specimens. Instead, cement is typically tested in the form of cement-sand mortar.
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
133
Testing Water Quality
107
When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
107


