船舶电气系统中接地保护传感器网络的最佳拓控制
Benxiang Wu1, Geng Li1, Jianhua Wu2
1Naval University of Engineering, Wuhan, Hubei, China.
Science progress
|March 28, 2024
概括
本研究介绍了使用无线传感器网络进行船舶环境监测系统的优化拓控制. 这种新方法增强了数据收集,减少了能源使用,并将传输延迟降至最低,以提高海上安全.
科学领域:
- 海洋安全和环境监测
- 无线传感器网络是无线传感器网络.
- 网络拓优化网络拓优化
背景情况:
- 智能监控船上环境信息对于事故预防和海上安全至关重要.
- 无线传感器网络 (WSN) 为实时船舶环境监测提供了具有成本效益,稳定和可靠的解决方案.
研究的目的:
- 为WSNs在船舶环境监测中提出一个最佳的拓控制算法.
- 为了最大限度地提高收集数据的满意度,同时最大限度地减少能源消耗和传输延迟.
主要方法:
- 模糊集群算法用于无线传感器网络集群头的选择.
- 亚梯度下降算法来确定数据收集量.
- 基于群优化的传感器关联方案来解决背包问题.
主要成果:
- 拟议的算法有效地减少了WSN中的能源消耗.
- 该算法显著减少了数据传输延迟.
- 确保在海上船舶电气系统中对接地保护的监控.
结论:
- 开发的最佳拓控制提高了船舶环境监测WSN的效率.
- 该方法平衡了数据收集需求与资源限制 (能源,延迟).
- 这有助于提高海上环境的安全性和运行可靠性.
更多相关视频
05:30Large Scale Energy Efficient Sensor Network Routing Using a Quantum Processor Unit
Published on: September 8, 2023
543
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
5.9K
相关概念视频
Zones of Protection
168
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
168
Line Protection with Impedance Relays
79
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
79
Radial System Protection
94
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
94
Electrical Systems
382
In electrical engineering, the analysis of networks composed of passive linear components — resistors (R), capacitors (C), and inductors (L) — is fundamental. These components are organized into circuits where the relationship between input and output can be analyzed using transfer functions. The transfer function of an RLC circuit, which relates the voltage across a capacitor to the input voltage, can be derived using Kirchhoff's laws.
To derive the transfer function, consider...
To derive the transfer function, consider...
382
Reclosers and Fuses
103
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
103
Insulation Coordination
129
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
129