在高温和低温下,高粘度热混合青的风湿学特性
Jun'an Lei1, Nanxiang Zheng2, Yuanyuan Wang1
1School of Civil Engineering and Architecture, HuBei University of Arts and Science, Xiangyang, Hubei, China.
PloS one
|March 28, 2024
概括
热混合添加剂EC和M1降低了高粘度青 (HVA) 的高温粘度. M1 提高了疲劳和低温性能,而 EC 提高了耐磨性,但降低了疲劳和低温性能.
科学领域:
- 材料科学 材料科学 材料科学
- 土木工程 土木工程是指土木工程.
- 青技术技术的使用
背景情况:
- 青的风学特性对道路性能至关重要.
- 了解热混合高粘度青 (HVA) 病理学对于其应用至关重要.
研究的目的:
- 为了研究两个热混合添加剂EC120 (EC) 和Evotherm M1 (M1) 对HVA的风湿性质的影响.
- 为了评估热混合HVA在高,中,低温度下的性能.
主要方法:
- 使用EC和M1.准备热混合HVA使用EC和M1.
- 风学性质测试包括布林尔旋转粘度,动态剪切风学 (温度,频率,振幅扫描) 和曲束风学.
- 测试是在-6°C至195°C的温度范围内进行的.
主要成果:
- 无论是EC还是M1,都有效地降低了高温下的HVA粘度,从而降低了建筑温度.
- 在0.6%的剂量下,M1提高了HVA疲劳耐力~30%,提高了低温性能.
- EC增加了化因子,但在4%的剂量下降了约9%的疲劳寿命,降低了低温性能.
结论:
- 热混合添加剂显著改变HVA的质性质.
- M1在疲劳和低温性能方面具有优势,而EC则以疲劳和低温性能为代价提高了抗变形性能.
- 发现有助于理解和促进热混合HVA应用.
相关概念视频
Hot Weather Concreting
64
Concreting at elevated temperatures accelerates the hydration process, leading to quicker setting but potentially reducing the long-term strength of the concrete structure. Additionally, low air humidity fosters rapid moisture loss from the concrete, resulting in reduced workability, pronounced plastic shrinkage, and a higher likelihood of crazing.
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
64
Design Example: Managing Concrete Workability
80
This example deals with managing the workability of concrete for a raft foundation project under hot weather conditions. Workability is crucial for ensuring the concrete is easy to place, compact, and finish. In this scenario, a slump test — a common method to measure the workability of fresh concrete — initially indicated low workability. This was attributed to the rapid water loss from the concrete mix, exacerbated by the high temperatures causing the course aggregates to heat up.
80
Cold Weather Concreting
72
When freshly poured concrete is exposed to freezing temperatures before it has set, the water within the concrete can freeze. This expansion disrupts the setting process, delays chemical reactions necessary for hardening, and increases the volume of pores within the hardened concrete, which weakens its overall structure. If the concrete manages to reach an appreciable strength before it freezes, the damage can be somewhat mitigated.
To counteract the negative impacts of cold weather, ensuring...
To counteract the negative impacts of cold weather, ensuring...
72
Surface Tension, Capillary Action, and Viscosity
27.7K
Surface Tension
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
27.7K
Viscosity of Fluid
398
Viscosity measures the resistance a fluid offers to flow and deformation. It results from internal friction between layers of fluid moving relative to one another. Dynamic viscosity, denoted by the Greek letter mu (μ), quantifies the force needed to move one fluid layer over another. For Newtonian fluids like water and air, the relationship between the shearing stress and the rate of shearing strain is linear, meaning their viscosity remains constant regardless of the applied stress.
398
Masonry in Cold and Hot Weather Conditions
88
In cold weather, masonry construction requires specific precautions to ensure mortar does not freeze before curing, as this can significantly weaken its strength and watertightness. Mortar temperature should be maintained between 60°F and 80°F to support proper hydration and curing. Below 40°F, mortar water must be heated, but should not exceed 120°F as high temperatures can reduce mortar's compressive and bond strength.
Other key practices include keeping masonry units...
Other key practices include keeping masonry units...
88


